※Contact TDK-Lambda concerning items not mentioned or items which are not clear.
5. Soldering Conditions / Cleaning Condi
5. Soldering Conditions / Cleaning Condi
5. Soldering Conditions / Cleaning Condi
5. Soldering Conditions / Cleaning Conditions / Installation Method
tions / Installation Method
tions / Installation Method
tions / Installation Method
5-1 Soldering Conditions
【DIP Model】
Perform soldering of the converter to the board according to the conditions shown in Table 5-1.
Soldering is to be performed only one time per pin.
Table 5-1 Solder Conditions for DIP Models
Method
Condition
Solder Dip
260℃ 10 sec Max.
Solder Iron
380℃ 3 sec Max.
【SMD Model】
Lead free solder / high temperature reflow process conditions are shown in Figure 5-1.
The number of times permitted for reflow is 1 time.
TP
225
Ty2
Ty1
部
品
表
面
温
度
(
℃
)
ハンダ付け時間(s)
A '
A
B
B '
C
A
A '
B
B '
C
1.0~3.0℃/sec
Ty1:150±10℃
Ty2:170±10℃
Ty1~Ty2:20~100sec
1.0~4.0℃/sec
TP:MAX 245℃
225℃以上:20~40sec
-1.0~-5.0℃/sec
Fig. 5-1 Reflow Process Conditions for SMD Models
5-2 Washing Conditions
We do not recommend board cleaning after soldering, we recommend not performing cleaning, but when cleaning becomes
necessary, perform it according to the conditions shown in Table 5-2
Table 5-2 Cleaning Fluid and Test Conditions
Cleaning Fluid
Cleaning Method
Time
Ultrasonic Wave 60℃
60 sec.
Cold Bath Cleaning R.T
60 sec.
Isopropyl Alcohol
Vapor Cleaning 83℃
60 sec.