※Contact TDK-Lambda concerning items not mentioned or items which are not clear. 

3. Inp

3. Inp

3. Inp

3. Input / Output Line Connection

ut / Output Line Connection

ut / Output Line Connection

ut / Output Line Connection    

3-1 Fuse 

Because there is no built-in fuse, use an external fuse in accordance with Table 3-1. 

In addition, when supplying input voltage from one DC power supply to multiple DC/DC converters, 

attach a fast breaking fuse to the input of each converter upon use.   

 

Put the fuse on the +Vin side when the 

Vin side is used for GND, and on the -Vin side when the +Vin side is used for GND. 

 

When a fuse breaks, the Alarm Signal does not operate. 

 

Table 3-1    Recommended Fuse Capacity 

Converter Type 

CC15-24xxSxx-E 

CC30-24xxSxx-E 

Fuse Capacity 

2A 

4A 

Converter Type 

CC15-48xxSxx-E 

CC30-48xxSxx-E 

Fuse Capacity 

1A 

2A 

 

3-2 Input Side External Capacitor 

This converter is equipped with a capacitor on the input side and does not need an external capacitor to be attached to the input 

terminal side when the length of the line connection from the DC power source is short (less than 1 meter is estimated). 

However, when the line to the input terminal is long, or when the inductance increases, operation may become unstable, therefore 

insert external capacitor Cin between the +Vin and 

Vin terminals. 

DC

Input

+Vin

-Vin

Fuse

Lin

Cin

 

Fig. 3-2-1    Cin is necessary when an inductance filter is inserted in the input line. 

 

DC

Input

+Vin

-Vin

Cin

Fuse

 

Fig. 3-2-2    Cin is necessary when the input line is long. 

 

Table 3-2    Recommended External Capacitor Cin Values 

Converter Type 

CC15-24xxSxx-E 

CC30-24xxSxx-E 

Recommended Cin Value 

33μF 

68μF 

Converter Type 

CC15-48xxSxx-E 

CC30-48xxSxx-E 

Recommended Cin Value 

10μF 

22μF 

Summary of Contents for CC15-xxxx-Sxx-E Series

Page 1: ...ot using the Remote Control function use it with either the RC terminal open or connected to the Vin terminal When not using the Alarm function use it with the ALM terminal in an open condition Use the PO terminal for controling multiple unit operation series parallel operation etc For single unit operation use the PO terminal in an open condition The converter is to be operated exclusively on DC ...

Page 2: ...Converter Type CC15 48xxSxx E CC30 48xxSxx E Fuse Capacity 1A 2A 3 2 Input Side External Capacitor This converter is equipped with a capacitor on the input side and does not need an external capacitor to be attached to the input terminal side when the length of the line connection from the DC power source is short less than 1 meter is estimated However when the line to the input terminal is long o...

Page 3: ...input voltage reverse polarity connection Damage may occur if reverse polarity voltage is applied to the input terminal When the possibility of the application of reverse polarity voltage exits attach an external protection circuit as shown in Figure 3 4 DC Input Vin Vin Fuse Fig 3 4 Reverse Connection Prevention Circuit 3 5 Output Side External Capacitor When connecting a pulse load to this conve...

Page 4: ...le voltmeter or oscilloscope used for measuring The TDK ripple noise measurement is made according to the method shown in Figure 3 6 Load Vout Vout Cout DC Input Vin Vin Oscilloscope Bw 100MHz 25mm R C 1 5m 50Ω Coaxial Cable JEITA attachment R 50Ω C 0 1μF 3 3V 5V output Cout 22μF 12V 15V output Cout 0 1μF Fig 3 6 Ripple Noise Voltage Measurement Circuit Caution when Adding External Capacitor Cout ...

Page 5: ... is ON If the RC terminal is set at H Level the output is OFF When the converter is in a latch stop condition because of a protection function after removing the abnormal factor use the Remote Control to turn the output OFF then turn ON after the lapse of 1 second minimum for recovery to occur Qrc Vin Vin R3 DC Input RC RC Control Signal R2 Qrc Vin Vin R3 R2 DC Input RC R1 RC Control Signal Fig 4 ...

Page 6: ...nnected together when an abnormality occurs and the alarm signal operates in 1 unit the other connected units can be stopped Converters having different output voltages can be connected This applies only to converters belonging to this series Use the ALM terminal at a maximum sink current of 10mA The maximum number of units to which the ALM terminal can be connected is 20 units 4 3 Simultaneous St...

Page 7: ...oved recovery can be achieved either by restarting the input power source or by using the remote control function 4 5 Over Voltage Protection These converters are equipped with a built in over voltage protection circuit When the output voltage becomes 115 145 of the rated voltage the over voltage protection circuit operates When the output current is less than 50 of the rated current depending on ...

Page 8: ... same type in series The maximum number of converters which can be operated in series is 2 When using series operation connect the Vin terminal Vin terminal PO terminal and ALM terminal of each converter to the same terminal of the other DC Input Vin Vin Vout Vout PO RC ALM Fuse SW Load Vin Vin Vout Vout PO RC ALM Fuse LED Fig 4 7 Example Series Operation Connection ...

Page 9: ...t the PO terminal and ALM terminal of each converter to the same terminal of the other As much as possible insure that the width length and material of the wiring used for connecting each converter to the load are identical There is the possibility that the current balance will collapse if there is a difference in the wiring from each respective converter to the load DC Input Vin Vin Vout Vout PO ...

Page 10: ...er Dip 260 10 sec Max Solder Iron 380 3 sec Max SMD Model Lead free solder high temperature reflow process conditions are shown in Figure 5 1 The number of times permitted for reflow is 1 time TP 225 Ty2 Ty1 部品表面温度 ハンダ付け時間 s A A B B C A A B B C 1 0 3 0 sec Ty1 150 10 Ty2 170 10 Ty1 Ty2 20 100sec 1 0 4 0 sec TP MAX 245 225 以上 20 40sec 1 0 5 0 sec Fig 5 1 Reflow Process Conditions for SMD Models 5 2...

Page 11: ...talling the converter on the board avoid having trace pattern etc in the slanted line area shown in Figure 5 3 because there is the possibility of an insulation defect occurring CC15 xxxxxSx E CC30 xxxxxSx E 38 2 29 6 33 5 38 2 34 7 1 75 1 75 34 7 1 75 1 75 Out line Out line Fig 5 2 Trace Pattern Prohibited Area ...

Reviews: