70
32072H–AVR32–10/2012
AT32UC3A3
7.6.12
Power and Oscillators Status Register
Name: POSCSR
Access Type:
Read-only
Offset:
0x54
Reset Value:
0x00000020
• BOD33DET: Brown out 3V3 detection
0: No BOD33 event
1: BOD33 has detected that power supply is going below BOD33 reference value.
• BODDET: Brown out detection
0: No BOD event
1: BOD has detected that power supply is going below BOD reference value.
• OSC32RDY: 32 KHz oscillator Ready
0: The 32 KHz oscillator is not enabled or not ready.
1: The 32 KHz oscillator is stable and ready to be used as clock source.
• OSC1RDY: OSC1 ready
0: Oscillator 1 not enabled or not ready.
1: Oscillator 1 is stable and ready to be used as clock source.
• OSC0RDY: OSC0 ready
0: Oscillator 0 not enabled or not ready.
1: Oscillator 0 is stable and ready to be used as clock source.
• MSKRDY: Mask ready
0: Mask register has been changed, masking in progress.
1: Clock are masked according to xxx_MASK
• CKRDY:
0: The CKSEL register has been written, and the new clock setting is not yet effective.
1: The synchronous clocks have frequencies as indicated in the CKSEL register.
• LOCK1: PLL 1 locked
0:PLL 1 is unlocked
1:PLL 1 is locked, and ready to be selected as clock source.
• LOCK0: PLL 0 locked
0: PLL 0 is unlocked
1: PLL 0 is locked, and ready to be selected as clock source.
31
30
29
28
27
26
25
24
-
-
-
-
-
-
-
-
23
22
21
20
19
18
17
16
-
-
-
-
-
-
BOD33DET
BODDET
15
14
13
12
11
10
9
8
-
-
-
-
-
-
OSC32RDY
OSC1RDY
7
6
5
4
3
2
1
0
OSC0RDY
MSKRDY
CKRDY
-
-
-
LOCK1
LOCK0
Summary of Contents for AT32UC3A3128
Page 61: ...61 32072H AVR32 10 2012 AT32UC3A3 PLLEN PLL Enable 0 PLL is disabled 1 PLL is enabled...
Page 592: ...592 32072H AVR32 10 2012 AT32UC3A3 Manchester Configuration Register on page 614...
Page 989: ...989 32072H AVR32 10 2012 AT32UC3A3 37 2 Package Drawings Figure 37 1 TFBGA 144 package drawing...
Page 991: ...991 32072H AVR32 10 2012 AT32UC3A3 Figure 37 3 VFBGA 100 package drawing...