Table 3–4. rx_dataoutfull[63:0] PLD Data Signal Descriptions (Part 1 of 6)
PLD Interface Description
Receive Signal Description
(Based on Stratix II GX Supported PLD Interface Widths)
8-bit PLD fabric interface
The following signals are used in 8-bit 8B/10B modes:
rx_dataoutfull[7:0]
: 8-bit decoded data (
rx_dataout
)
rx_dataoutfull[8]
: Control bit (
rx_ctrldetect
)
rx_dataoutfull[9]
: Code violation status signal. It indicates error detected
in
rx_dataoutfull[7:0]
, which is replaced by invalid code-group (invalid
or running disp.error) in GIGE mode. In PCI Express, when code violation
occurs, the EDB character is placed on the erroneous data byte (= K30.7)
(
rx_errdetect
)
rx_dataoutfull[10]
:
rx_syncstatus
rx_dataoutfull[11]
: Disparity error status signal. It indicates disparity
error detected in
rx_dataoutfull[7:0]
(
rx_disperr
)
rx_dataoutfull[12]
: Pattern detect status signal (
rx_patterndetect
)
rx_dataoutfull[13]
: Reserved
rx_dataoutfull[14]
: Reserved
rx_dataoutfull[14:13]
: PIPE/PCI-E mode: 2'b00: data OK; 2'b01: 1 SKP
deletion; 2'b10: elastic buffer underflow if data is 0xFE, else 1 SKP insertion;
2b11: elastic buffer overflow (
rx_pipestatus
)
rx_dataoutfull[15]
: Reserved
The following signals are used in 8-bit SONET/SDH mode:
rx_dataoutfull[7:0]
: 8-bit un-encoded data (
rx_dataout
)
rx_dataoutfull[8]
:
rx_a1a2sizeout
rx_dataoutfull[10]
:
rx_syncstatus
rx_dataoutfull[11]
: Reserved
rx_dataoutfull[12]
:
rx_patterndetect
10-bit PLD fabric interface
rx_dataoutfull[9:0]
: 10-bit un-encoded data (
rx_dataout
)
rx_dataoutfull[10]
:
rx_syncstatus
rx_dataoutfull[11]
: Reserved
rx_dataoutfull[12]
:
rx_patterndetect
rx_dataoutfull[13]
: Reserved
rx_dataoutfull[14]
: Reserved
rx_dataoutfull[15]