CTS2

P.  / 3

EM-902

COMPONENT IDENTIFICATION

Base Socket

Current Probe

Specification Label

Body

Mounting Attachment

 FRONT PANEL CONFIGURATIONS

BEFORE USE ....

Thank  you  for  choosing  M-System.    Before  use,  check  the 
package you received as below.
If  you  have  any  problems  or  questions  with  the  product, 
please contact M-System's Sales Office or representatives.

■ 

PACKAGE INCLUDES:

  Signal conditioner (body + base socket) ..................(1)
  Current probe ...........................................................(1)
  Current probe mounting attachments ....................(2)

■ 

MODEL NO.

Check that model No. described on specification label is ex-
actly what you ordered.

■ 

INSTRUCTION MANUAL

This manual describes necessary points of caution when you 
use this product, installation, connection and basic mainte-
nance procedures.

POINTS OF CAUTION

■ 

POWER INPUT RATINGS

•  Power  input  ratings  are  specified  by  the  model  number 
suffix code.  Check the power input voltage for the unit on 
the specification label.
   AC power: rating ±10%, 50/60 ±2 Hz, approx. 2VA
   DC power: rating ±10%, approx. 2W
     

(85 – 150V for 110V rating)

■ 

GENERAL

• Before you remove the unit from its base socket or mount 
it, turn off the power supply and input signal for safety.

■ 

ENVIRONMENT

• When heavy dust or metal particles are present in the air, 
install the unit inside proper housing and ventilate it.
• Do not install the unit where it is subjected to continuous 
vibration.  Do not apply physical impact to the unit.
• Environmental temperature must be within -5 to +60°C 
(23  to  140°F)  for  the  transmitter  and  -10  to  +55°C  (14  to 
131°F)  for  the  probe,  with  relative  humidity  within  15  to 
85% RH for the probe, 30 to 90% RH for the transmitter in 
order to ensure adequate life span and operation.
• Do not cover the ventilation slits with cables, etc.

■ 

WIRING

•  Do  not  install  cables  (power  supply,  input  and  output) 
close to noise sources (relay drive cable, high frequency line, 
etc.).
•  Do  not  bind  these  cables  together  with  those  in  which 
noises are present.  Do not install them in the same duct.

■ 

AND ....

• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for sat-
isfying complete performance described in the data sheet.

Range Selector

*

   4 : 300 (3000) A
   3 : 150 (1500) A
   2 :   60 (  600) A
   1 :   30 (  300) A

Zero Adj.
Span Adj.

SENSOR  INPUT

ON

4

3

2

1

Probe Connector

*

(     ) for input 3000A type.

HIGH AC CURRENT TRANSMITTER

(wide bandwidth)

MODEL

CTS2

INSTRUCTION MANUAL