2–216
Altera Corporation
Stratix II GX Device Handbook, Volume 2
October 2007
Reset Control and Power Down
■
gxb_powerdown
. The
gxb_powerdown
signal powers down the
entire transceiver block. All digital and analog circuits are also reset.
This signal operates independently from the other reset signals. The
minimum pulse width for gxb_powerdown signal is 100 ns
Synchronization is performed after any reset condition. You must
determine when the data is valid after reset (for example, by using the
rx_syncstatus
signal).
Table 2–52
shows the blocks affected by each
reset and power-down signal.
Table 2–52. Blocks Affected by Reset and Power-Down Signals (Part 1 of 2)
Transceiver Blocks
rx_digitalreset
rx_analogreset
tx_digitalreset
gxb_powerdown
Transmitter phase
compensation FIFO
buffer and byte
serializer
v
v
Transmitter 8B/10B
encoder
v
v
Transmitter serializer
v
Transmitter analog
circuits
v
Transmitter PLLs
v
Transmitter XAUI
state machine
v
v
Transmitter analog
circuits
v
BIST generators
v
v
Receiver deserializer
v
Receiver word
aligner
v
v
Receiver deskew
FIFO buffer
v
v
Receiver rate
matcher
v
v
Receiver 8B/10B
encoder
v
v
Receiver phase
compensation FIFO
buffer and byte
deserializer
v
v
Receiver PLL and
CRU
v
v