3–144
Altera Corporation
Stratix II GX Device Handbook, Volume 2
October 2007
Adaptive Equalization (AEQ)
Power Down Options
The AEQ hardware consumes approximately 80 mW power (typical) per
channel. Therefore, the dynamic reconfiguration controller provides
options to dynamically power down the AEQ hardware. The options are:
■
Power down for a single channel
■
Power down for all channels
Power Down for a Single Channel
When you use this option, the ALT2GXB_RECONFIG controller powers
down the AEQ hardware in the selected channel specified by the
logical_channel_address
value. Before powering down the AEQ
hardware, the ALT2GXB_RECONFIG reads the adaptive equalization
settings, translates them to the nearest available manual equalization
setting, and automatically writes the translated manual equalization
settings into the transceiver channel. To read the translated manual
equalization values, perform a read operation using the
PMA controls
option. The translated manual equalization values are available in the
corresponding byte positions of the
rx_eqctrl_out
port. For example,
assume that you perform an AEQ write using this option to power down
the AEQ hardware in logical channel 4. When you perform a read
operation using the
PMA controls
option, the translated manual
equalization values are available in
rx_eqctrl_out
port in bits 19
down to 16, as shown in
Figure 3–71
.