Altera Corporation
6–5
October 2007
Stratix II GX Device Handbook, Volume 2
Specifications & Additional Information
Table 6–3
shows the valid data code-groups.
K28.3
7C
8’b011_11100
10’b001111_0011
10’b110000_1100
K28.4
9C
8’b100_11100
10’b001111_0010
10’b110000_1101
K28.5
(1)
BC
8’b101_11100
10’b001111_1010
10’b110000_0101
K28.6
DC
8’b110_11100
10’b001111_0110
10’b110000_1001
K28.7
FC
8’b111_11100
10’b001111_1000
10’b110000_0111
K23.7
F7
8’b111_10111
10’b111010_1000
10’b000101_0111
K27.7
FB
8’b111_11011
10’b110110_1000
10’b001001_0111
K29.7
FD
8’b111_11101
10’b101110_1000
10’b010001_0111
K30.7
FE
8’b111_11110
10’b011110_1000
10’b100001_0111
Note to
Table 6–2
:
(1)
K28.5 is a comma code used for word alignment and indicates an IDLE state.
Table 6–2. Supported K Codes (Part 2 of 2)
K Code
Octal Value
8-Bit Code
HGF_EDCBA
10-Bit Code RD-
abcdei_fghj
10-Bit Code RD+
abcdei_fghj
Table 6–3. Valid Data Code-Groups (Part 1 of 9)
Code-Group Name
Octet Value
Octet Bits
HGF EDCBA
Current RD-
Current RD+
abcdei fghj
abcdei fghj
D0.0
00
000 00000
100111 0100
011000 1011
D1.0
01
000 00001
011101 0100
100010 1011
D2.0
02
000 00010
101101 0100
010010 1011
D3.0
03
000 00011
110001 1011
110001 0100
D4.0
04
000 00100
110101 0100
001010 1011
D5.0
05
000 00101
101001 1011
101001 0100
D6.0
06
000 00110
011001 1011
011001 0100
D7.0
07
000 00111
111000 1011
000111 0100
D8.0
08
000 01000
111001 0100
000110 1011
D9.0
09
000 01001
100101 1011
100101 0100
D10.0
0A
000 01010
010101 1011
010101 0100
D11.0
0B
000 01011
110100 1011
110100 0100
D12.0
0C
000 01100
001101 1011
001101 0100
D13.0
0D
000 01101
101100 1011
101100 0100
D14.0
0E
000 01110
011100 1011
011100 0100
D15.0
0F
000 01111
010111 0100
101000 1011