Altera Corporation
3–23
October 2007
Stratix II GX Device Handbook, Volume 2
Stratix II GX Dynamic Reconfiguration
■
Error
: The ALT2GXB_RECONFIG provides this status signal when
you select the
Enable illegal mode checking
option or the
Enable
self recovery
option in the
Error checks/data rate switch
tab. The
conditions under which the
error
signal is asserted, when the
above two options are enabled, are:
●
Enable illegal mode checking
option—when you select this
option, the dynamic reconfiguration controller checks whether
an attempted operation falls under one of the seven conditions
listed below. The dynamic reconfiguration controller detects
these conditions within two
reconfig_clk
cycles, de-asserts
the
busy
signal, and asserts the
error
signal for two
reconfig_clk
cycles.
1. PMA controls - read operation:
•
None of the analog PMA read output ports
(
rx_eqctrl_out
,
rx_eqdcgain_out
,
tx_vodctrl_out
,
tx_preemp_0t_out
,
tx_preemp_1t_out
, and
tx_preemp_2t_out
) are
selected in the ALT2GXB_RECONFIG MegaWizard
•
reconfig_mode_sel
is set to
0
•
read
signal is asserted
2. PMA controls - write operation:
•
None of the analog PMA control write input ports
(
rx_eqctrl
,
rx_eqdcgain
,
tx_vodctrl
,
tx_preemp_0t
,
tx_preemp_1t
, and
tx_preemp_2t
)
are selected
•
reconfig_mode_sel
is set to
0
•
write_all
signal is asserted
3. Channel and/or TX PLL reconfiguration - read operation:
•
reconfig_mode_sel
input port is set to
1
,
4
,
5
, or
6
•
read
signal is asserted
4. Data rate switch - write operation with unsupported value:
•
The
rate_switch_ctrl[1:0]
input port is set to
11
•
reconfig_mode_sel
input port is set to
4
(if other
reconfiguration mode options are selected in the
Reconfiguration settings
tab)
•
write_all
is asserted