Receiver Modules
restores the 8-bit data + 1-bit control identifier from the 10-bit code. In
double-width mode, there are two 8B/10B decoders cascaded together,
which restores the 16-bit (2× 8-bit) data + 2-bit (2× 1-bit) control identifier
from the 20-bit (2× 10-bit) code. This 8B/10B decoder conforms to the
IEEE 802.3 1998 edition standards.
Figure 2–80. 8B/10B Decoder
Note to
Figure 2–80
:
(1)
Status signals include
rx_ctrldetect
,
rx_disperr
, and
rxerrdectect
.
Single-Width Mode
In single-width mode, the Stratix II GX 8B/10B decoder operates in a
similar fashion as the Stratix GX 8B/10B decoder. The highlighted data
path in
Figure 2–81
is active in the single-width mode.
Figure 2–81. Active Data Path in Single-Width Mode
Note to
Figure 2–81
:
(1)
Status signals include
rx_ctrldetect
,
rx_disperr
, and
rxerrdectect
.
8B/10B
Decoder
MSByte
datain[19..10]
To Byte
Deserializer
dataout[15..8]
Status Signals[1]
(1)
8B/10B
Decoder
LSByte
datain[9..0]
dataout[7..0]
Status Signals[0]
From Rate
Matcher
(1)
8B/10B
Decoder
MSByte
datain[19..10]
To Byte
Deserializer
dataout[15..8]
Status Signals[1]
(1)
8B/10B
Decoder
LSByte
datain[9..0]
dataout[7..0]
Status Signals[0]
From Rate
Matcher
(1)