Channel and PMA Controls Reconfiguration
Section I
Use the following steps to generate a MIF for GIGE and SONET/SDH
OC48 modes:
1.
Generate the ALT2GXB instantiation for GIGE mode.
2.
Generate the AL2GXB_RECONFIG instantiation.
3.
Create a top-level design and generate the MIF for the GIGE
protocol mode.
4.
Modify the ALT2GXB instantiation for SONET /SDH OC48 mode.
5.
Generate the MIF for SONET/SDH OC48 mode.
6.
Initialize two memory elements with the MIF contents and write
logic to select the MIF and to control the ALT2GXB_RECONFIG
instance.
Step 1—Generate the ALT2GXB Instantiation for GIGE Mode:
This example shows the ALT2GXB instantiation for one-channel GIGE
and SONET/SDH mode.
1.
Set the protocol to
GIGE
mode in the first screen.
Select the following control and status signals:
●
rx_digitalreset
●
tx_digitalreset
●
rx_analogreset
●
rx_pll_locked
●
rx_freqlocked
2.
Add the other required status signals.
f
For a list of ALT2GXB signals and their functionality, refer to
“Stratix II GX ALT2GXB Ports List” on page 2–2
in the
Stratix II GX
Transceiver Architecture Overview
chapter in volume 2 of the
Stratix II GX
Device Handbook
.
3.
In the
Reconfig
tab, set the following options:
●
If you need control of the transceiver PMA values, select the
Analog PMA controls. For more information about PMA
controls, refer to
“Introduction” on page 3–1
.