Altera Corporation
4–33
October 2007
Stratix II GX Device Handbook, Volume 2
Stratix II GX ALT2GXB Megafunction User Guide
Table 4–11
describes the available options on page 3 of the MegaWizard
Plug-In Manager for your ALT2GXB custom megafunction variation.
Table 4–11. MegaWizard Plug-In Manager Options (Page 3 for PIPE Mode) (Part 1 of 2)
ALT2GXB Setting
Description
Reference
Which protocol will you be
using?
Determines the specific protocol or modes under
which the transceiver operates. For the PIPE mode,
you must select the
PCI Express (PIPE)
protocol.
Which subprotocol will you
be using?
In PIPE mode, the subprotocols are the lane
configurations: ×1, ×4, or ×8 modes.
PIPE Mode and Clock
Multiplier Unit sections in
the
Stratix II GX
Transceiver Architecture
Overview
chapter in
volume 2 of the
Stratix II GX Device
Handbook.
Enforce default settings for
this protocol
Selecting this option skips the
PCI
page in the PIPE
MegaWizard Plug-In Manager. The
PCI
page
allows you to select the PIPE-specific ports for your
design. If you select this option, all PIPE-specific
ports are used.
What is the operation mode? Only the receiver and transmitter (full duplex) mode
is allowed in the PIPE mode. Receiver only and
transmitter only modes are not allowed.
What is the number of
channels?
This determines how many duplicate channels this
ALT2GXB instance contains. In a ×4 subprotocol,
the number of channels increments by 4. In a ×8
subprotocol, the number of channels increment
by 8.
What is the deserializer block
width?
PIPE mode only operates in a single-width mode.
Double-width mode is not allowed.
What is the channel width?
This option determines the transceiver to PLD
interface width. In PIPE mode, 8 bits and 16 bits are
allowed.
What would you like to base
the setting on?
This option is not used because the data rate is
fixed at 2.5 Gbps for PIPE mode.
What is the data rate?
This option is not used because the data rate is
fixed at 2.5 Gbps for PIPE mode.
What is the input clock
frequency?
Determines the input reference clock frequency for
the transceiver. In PIPE mode, only 100 MHz is
allowed.
PIPE Mode section in the
Stratix II GX Transceiver
Architecture Overview
chapter in volume 2 of the
Stratix II GX Device
Handbook.