3–38
Altera Corporation
Stratix II GX Device Handbook, Volume 2
October 2007
Channel and PMA Controls Reconfiguration
4.
Setup core clocking (refer to
“Transmitter Core Clocking” on
page 3–45
and
“Receiver Core Clocking” on page 3–48
for more
information).
5.
Finish the ALT2GXB configuration.
6.
Repeat the previous 5 steps with the same TX PLL base setting and
different local clock divider settings.
7.
Group core clocking.
8.
Lock down the pin assignments for the clocks and generate the
MIFs for above instances.
Steps
1
and
2
are the only steps related to the local clock divider settings.
Step
4
is a mandatory step and is an important part of clocking in every
channel reconfiguration (refer to
Figure 3–17
).
Figure 3–17. ALT2GXB Instance—TX/RX Local Clock Divider