Altera Corporation
5–13
October 2007
Stratix II GX Device Handbook, Volume 2
Stratix II GX ALT2GXB_RECONFIG Megafunction User Guide
Figure 5–7
shows page 7 (the Simulation Libraries page) of the
MegaWizard Plug-In Manager for the Dynamic Reconfiguration
selection.
Click
Next
.
Table 5–4. MegaWizard Plug-In Manager Options (Page 6)
ALT2GXB_RECONFIG Setting
Description
Reference
Enable illegal mode checking
When this option is selected, the
ALT2GXB_RECONFIG MegaWizard provides the
error
output port. The dynamic reconfiguration
controller checks for specific unsupported options
within 2
reconfig_clk
cycles, de-asserts the
busy
signal and asserts the
error
output port for
2
reconfig_clk
cycles. The dynamic
reconfiguration controller does not execute the
unsupported operation.
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook
.
Enable self recovery
When this option is selected, the
ALT2GXB_RECONFIG MegaWizard provides the
error
output port. The dynamic reconfiguration
controller quits an operation if it did not complete
within the expected number of clock cycles. After
recovering from the illegal operation, the dynamic
reconfiguration controller de-asserts the
busy
signal and asserts the
error
output port for 2
reconfig_clk
cycles.
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook
.
Use the
rate_switch_out
Port to read out the current data rate division values.
This optional output status port reads out the
current setting on the CMU local divider.
00 — Division of 1
01 — Division of 2
10 — Division of 4
11 — illegal value (do not use this value)
Stratix II GX Dynamic
Reconfiguration
chapter in volume 2 of
the
Stratix II GX Device
Handbook
.