background image

©2016 DEKIST Co., Ltd.                                                                                                                                  Rev. 1.6 

RN172 

RADIONODE WiFi Data Transmitter   

 

 

Supports WiFi

 

 

Temperature/Humidity, Thermocouple, PT100, 4-20mA 

 

For making phone calls/sending text messages 

 

Supports cloud monitoring(Tapaculo365) 

 

Supports MODBUS TCP /HTTP GET Method 

 

2CH LED display on the front 

 

Sound buzzer inside 

 
Product Overview 

The  RN172  WiFi  data  transmission  device 
delivers the data  from the UA sensor products 
to  a  remote  receiver  through  the  WiFi.  The 
remote  receiver  refers  to  the  PCs  where  the 
Tapaculo  software  is  installed,  a  cloud 
monitoring service (Tapaculo

®

365), or the web 

server developed by the user. 

 

The RN172 device is equipped with a display on 
the front to show the data, and with a buzzer to 
sound  the  alarm  when  the  limit  value  is 
exceeded.  The  system  also  provides  a  cloud 
monitoring service, one of the advanced features 
of the system (Tapaculo

®

365). Using this service, 

it  is  possible  to  send  an  emergency 
SMS/telephone alarm or schedule to send e-mail 
reports. 

 

Purpose

 

•  Gathering sensor information 

      through the network 

•  Establishment of an integrated 

  control system 

•  Establishing an industrial alarm 

system 

 

Application

 

•  Food storage (freezer, refrigerated) 
•  Bio laboratory 
•  Building energy use monitoring 
•  Medicine storage 
•  Semiconductor production line 

 

Order number

 

•MODEL : RN171 

Block diagram 

 

Summary of Contents for RN172-W

Page 1: ...ice Tapaculo 365 or the web server developed by the user The RN172 device is equipped with a display on the front to show the data and with a buzzer to sound the alarm when the limit value is exceeded The system also provides a cloud monitoring service one of the advanced features of the system Tapaculo 365 Using this service it is possible to send an emergency SMS telephone alarm or schedule to s...

Page 2: ...APACULO365 COM USB Port For connecting to the PC for setting or connecting with the UA series product Making phone calls Supported TAPACULO365 COM Compatible USB sensors Use RADIONODE UA series Cloud monitoring S2 TAPACULO365 COM LOGIN Display LED display on the front for displaying Data or IP add d1 Data transmission frequency Can be configured every minute minimum Mounting Direct attachment thro...

Page 3: ...2_XXXX Step 2 After connecting the RN172 unit to the WiFi access 192 168 1 3 through the web browser Then access RN172 through your mobile phone Step 3 Press the WiFi Scan button to search for a WiFi AP nearby Step 4 Select the SSID of the AP to be used by the RN172 in the future Then input the password and save The display of the RN172 will show SAVE DONE and the saving is completed The password ...

Page 4: ...s a USB sensor along with the DC power adapter Then the basic function of the RN172 data transmission will be activated To make changes in the internal settings of the RN172 connect the USB cable to the PC with a 1 1 arrangement without a power source Launch the RADIONODE terminal SW on the PC When the background color is changed to green input radionode114 to access the configuration screen Radio...

Page 5: ...o it The Tapaculo Lite software provided as a part of the package is used to detect a device and to make requests for the data to the device The data received from the device is saved in the DB 4 2 Data logging in a remote location Via the internet the product can be used to gather information from other devices located in a remote place Each RN172 device will do with a private IP from the interne...

Page 6: ...hen the RADIONOTE terminal software is launched in the PC it automatically searches for a COM port and connects to it When it is connected to a COM port the background will turn green Also you can use a Telnet terminal to access the same console menu As the system is set to the DHCP mode by default you can view the IP address on the LED display when the system is powered up When establishing a con...

Page 7: ...Network Setup 2 System Setup 3 Buzzer Siren Setup 4 HTTP Destination Setup 5 MODBUS TCP Setup 9 Quit Back to normal Operation 5 1 Network setting 1 NETWORK SETUP MENU A Set DHCP OFF B Set IP Address 000 000 000 000 C Set GATEWAY Address 192 168 137 002 D Set DNS1 Address 192 168 137 002 E Set DNS2 Address 000 000 000 000 F Set SUBNET MASK 255 255 255 000 G Set VMAC 001EC01268E4 H Set UDP Broadcast...

Page 8: ... 2 System configuration 2 SYSTEM SETUP MENU A Set Device Name DEVICE 001ec01268e4 B Set Destination of HTTP TAPACULO365 C Set HTTP Update Interval 5 Min G Set FND Display Mode CH1 CH2 ON H Set Debug Print OFF Q Quit A Change the name of the device The default value is Device MAC address B Select the transmission protocol for the data gathered You can choose TAPACULO365 or CUSTOMER SERVER Use the C...

Page 9: ...172 or not to SOUND ON OFF G Turn the remote alarm lamps siren ON OFF The alarm lamp model supported is ST56EL ETNS 2 WS by QLIGHT CO LTD H Input the IP of the remote alarm lamp I Input the port of the remote alarm lamp 5 4 HTTP Request setting 4 HTTP DESTINATION SETUP MENU A Set HTTP Host URL 100 10 10 112 B Set HTTP Host Port 80 C Set HTTP NMAC 0000D880393E05ED D Set HTTP DATAIN File test jsp Q ...

Page 10: ...IT VALUE 16BIT LOW OFFSET 1 CH1 FLOATING 32BIT VALUE 16BIT HIGH OFFSET 2 CH2 FLOATING 32BIT VALUE 16BIT LOW OFFSET 3 CH2 FLOATING 32BIT VALUE 16BIT HIGH OFFSET 4 CH1 INTEGER 16BIT VALUE 16BIT OFFSET 5 CH2 INTEGER 16BIT VALUE 16BIT A Set MODBUS TCP PORT 502 B SetByteReverse 0 1 Reversed 0 None Q Quit A Change the port number used by MODBUS TCP Normally the port number is set to 502 B Turn Byte Reve...

Page 11: ...e is powered up it buzzes three times to inform the user of the current IP address and the screen will show the last two digits of the IP address Normally an internet router assigns 192 168 0 1 as the IP address with the last digit varying Expression of the data Expression of the IP USB Sensor Most of the data show the current value The example below shows that the temperature is 19 2 and humidity...

Page 12: ...Appears when a connection is being established with a WiFi network Means that the attempt to establish a WiFi network connection failed In this case the SSID or the password can be wrong Means that the connection to the WiFi network has been successfully established Conn TOAP CONN FAIL CONN SUCC SSID Password saved WiFi configuration mode WiFi signal strength Appears when the SSID and password set...

Page 13: ...configuration CONSOLE MODE ATSRESET Resets the RN172 RESET ATSMODEL Shows the model name of the RN172 product ATSMODEL RN171 W B U Z Z E R ATBSET Temporarily activates the internal buzzer of the RN172 OK ATBAL OFF CH1 CH2 OR AND Chooses the alarm condition OFF Do not use the alarm CH1 Alarm activated on Channel 1 CH2 Alarm activated on Channel 2 OR Alarm activated on CH1 or CH2 AND Alarm activated...

Page 14: ...by RN 171 utc The Unix Timestamp from the default NTP of RN171 If the RN171 device fails to establish a connection with an external NTP server it will provide incorrect time information This device connects to pool ntp org tapaculo365 com to retrieve the time information __device Uses the MAC address as the unique ID of the node from which the information has been transmitted The NMAC information ...

Page 15: ...igits are ignored and only the integers are delivered Transaction ID Protocol ID and Unit ID are internally ignored Whatever value you input through them they will use 3 as the function code READ HOLDDING REGISTER FUNCTION CODE 3 Channel Address Index 16Bit 16Bit Byte Reverse Value CH1 4 Byte Floating 0 0x3333 0x3333 27 9 1 0x41df 0xdf41 CH2 4 Byte Floating 2 0x999a 0x9a99 29 2 3 0x41e9 0xe941 CH1...

Page 16: ...onnection How to check the status during installation Unregistered device The LED on the front blinks in red and green alternately once the power is on Registered device When the power is on you will hear the melody When there is an error with the internet connection There is no reaction when you connect the power Only the green light will remain on 10 2 Registering a new device Access S2 TAPACULO...

Page 17: ...that transmits the actual data Move to the New Channel menu You will find the data channel that is generated by the newly added device detected If the new channel is not detected wait until the next data update or reboot the device so that the channel can be detected Click the Channel Registration button A pop up window will appear Input the channel name and select the unit to complete the registr...

Page 18: ...on you may use the various features such as the report dashboard or alarm setting of S2 Tapaculo365 com All the customers who purchased this product may use these features basically free of charge If you require advanced features you may switch to the paid services Ex Dashboard d2 Ex Report d3 ...

Page 19: ...es detected as Broadcasting Of these select the device whose data you wish to save Select the time interval for saving the data from among 1 sec 5 secs 10 secs 1 minute 5 minutes and 10 minutes Choose carefully as you cannot change these settings once the project is created If the broadcasting port is blocked by a firewall the device will not be detected automatically In this case push Manual Add ...

Page 20: ...to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CAUTION Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user s authority to operate the equipment KCC 인증 d4 A급 기기 업무용 방송통신기자재 이 기기는 업무용 A...

Reviews: