718
Appendix D
Softkey Functions
System Menu
System Menu
Key Operation
Function
SCPI Command
Displays softkeys for performing limit tests and accessing control and management functions on the analyzer.
Outputs the current screen to a printer.
:HCOP
Abort Printing
Aborts printing.
:HCOP:ABOR
Printer Setup
Opens a dialog box for setting up the printer.
None
Invert Image
Inverts the colors of the screen display.
:HCOP:IMAG
Dump Screen Image
Opens a dialog box for saving the screen image in BMP (Windows or
OS/2 bitmap) format.
:MMEM:STOR:IMAG
Multiport Test Set
Setup
Displays softkeys for setting the E5091A control.
Test Set 1
Displays the model selected for test set 1.
Select Test Set
Displays the selected model.
E5091_9
Selects the 9-port model (E5091A-009).
:SENS{1-16}:MULT1:NAME E5091_9
E5091_13
Selects the 13-port model (E5091A-016).
:SENS{1-16}:MULT1:NAME E5091_13
E5091_16
Selects the 16-port model (E5091A-016).
:SENS{1-16}:MULT1:NAME E5091_16
Cancel
Returns to the softkey display screen one level higher.
Control
Enables/disables control of the E5091A.
:SENS{1-16}:MULT1:STAT
Property
Enables/disables the display of the E5091A properties.
:SENS{1-16}:MULT1:DISP
Port 1
Displays softkeys for selecting a test port of the E5091A to which you want to connect port 1.
A1
Selects test port A1.
:SENS{1-16}:MULT1:PORT1 A1
A2
*1
Selects test port A2.
:SENS{1-16}:MULT1:PORT1 A2
Selects test port A3.
:SENS{1-16}:MULT1:PORT1 A3
Selects test port A4.
:SENS{1-16}:MULT1:PORT1 A4
A
Selects test port A.
:SENS{1-16}:MULT1:PORT1 A
T1
Selects test port T1.
:SENS{1-16}:MULT1:PORT1 T1
Selects test port T2.
:SENS{1-16}:MULT1:PORT1 T2
Selects test port T3.
:SENS{1-16}:MULT1:PORT1 T3
Cancel
Returns to the softkey display screen one level higher.
Port 2
Displays softkeys for selecting a test port of the E5091A to which you want to connect port 2.
Selects test port B1.
:SENS{1-16}:MULT1:PORT2 B1
Selects test port B2.
:SENS{1-16}:MULT1:PORT2 B2
Selects test port B3.
:SENS{1-16}:MULT1:PORT2 B3
Selects test port B4.
:SENS{1-16}:MULT1:PORT2 B4
T1
Selects test port T1.
:SENS{1-16}:MULT1:PORT2 T1
T2
Selects test port T2.
:SENS{1-16}:MULT1:PORT2 T2
Selects test portT3.
:SENS{1-16}:MULT1:PORT2 T3
Selects test port T4.
:SENS{1-16}:MULT1:PORT2 T4
Cancel
Returns to the softkey display screen one level higher.
Summary of Contents for E5070B
Page 6: ......
Page 30: ...24 Contents ...
Page 34: ...28 Chapter1 Precautions Before contacting us ...
Page 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Page 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Page 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Page 634: ...628 AppendixB Troubleshooting Warning Message ...
Page 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Page 740: ...734 AppendixE General Principles of Operation Data Processing ...
Page 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...