Appendix D
681
Softkey Functions
Calibration Menu
D. Sof
tke
y
Fu
nctions
(Continued)
Modify Cal Kit
Label Kit
Allows the user to label the calibration kit.
:SENS{1-16}:CORR:COLL:CKIT:LAB
Restore Cal Kit
Displays softkeys for initializing the definition of calibration kit.
OK
Restores the definition of the calibration kit selected by
Cal Kit
to
factory default settings.
:SENS{1-16}:CORR:COLL:CKIT:RES
Cancel
Returns to the softkey display screen one level higher.
Export Cal Kit...
Exports the contents of the calibration kit to a file.
:MMEM:STOR:CKIT{1-20}
Import Cal Kit...
Imports a saved calibration kit file.
:MMEM:LOAD:CKIT{1-20}
Return
Returns to the softkey display screen one level higher.
Port Extensions
Displays softkeys for extending ports.
Auto Port
Extension
Displays softkeys for setting the auto port extension.
Select Ports
Displays softkeys for selecting the test port with which you want to perform the auto port extension.
Port 1
Selects test port 1
:SENS{1-16}:CORR:EXT:AUTO:PORT 1
Port 2
Selects test port 2
:SENS{1-16}:CORR:EXT:AUTO:PORT 2
Port 3
Selects test port 3
:SENS{1-16}:CORR:EXT:AUTO:PORT 3
Port 4
Selects test port 4
:SENS{1-16}:CORR:EXT:AUTO:PORT 4
Return
Returns to the softkey display screen one level higher.
Measure OPEN
Executes the measurement of the open standard.
All
Executes the measurement for all the selected ports.
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
Port 1
Executes the measurement for test port 1.
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
Port 2
Executes the measurement for test port 2.
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
Port 3
Executes the measurement for test port 3.
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
Port 4
Executes the measurement for test port 4.
:SENS{1-16}:CORR:EXT:AUTO:MEAS OPEN
Return
Returns to the softkey display screen one level higher.
Measure
SHORT
Executes the measurement of the short standard.
All
Executes the measurement for all the selected ports.
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
Port 1
Executes the measurement for test port 1.
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
Port 2
Executes the measurement for test port 2.
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
Port 3
Executes the measurement for test port 3.
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
Port 4
Executes the measurement for test port 4.
:SENS{1-16}:CORR:EXT:AUTO:MEAS SHOR
Return
Returns to the softkey display screen one level higher.
Method
Sets the frequency calculated by the auto port extension function.
Current Span
Sets the current sweep range.
:SENS{1-16}:CORR:EXT:AUTO:CONF CSPN
Active Marker
Sets the frequency of the active marker.
:SENS{1-16}:CORR:EXT:AUTO:CONF AMKR
User Span
Sets the arbitrary start value and stop value.
:SENS{1-16}:CORR:EXT:AUTO:CONF USPN
User Span
Start
Sets the start value.
:SENS{1-16}:CORR:EXT:AUTO:STAR
User Span
Stop
Sets the stop value.
:SENS{1-16}:CORR:EXT:AUTO:STOP
Return
Returns to the softkey display screen one level higher.
Key Operation
Function
SCPI Command
Summary of Contents for E5070B
Page 6: ......
Page 30: ...24 Contents ...
Page 34: ...28 Chapter1 Precautions Before contacting us ...
Page 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Page 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Page 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Page 634: ...628 AppendixB Troubleshooting Warning Message ...
Page 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Page 740: ...734 AppendixE General Principles of Operation Data Processing ...
Page 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...