Appendix D
671
Softkey Functions
Calibration Menu
D. Sof
tke
y
Fu
nctions
(Continued)
Calibrate
3-Port TRL Cal
Reflect
Displays softkeys for executing reflection calibrations. Symbols x, y and z refer to the three test ports selected in
the
Select Ports
menu (x, y, and z are always 1, 2, and 3, respectively, for models with Option 313 or 314).
Port x
Reflect
Executes a OPEN/SHORT reflection calibration on test port x.
:SENS{1-16}:CORR:COLL:TRLR x
Port y
Reflect
Executes a OPEN/SHORT reflection calibration on test port y.
:SENS{1-16}:CORR:COLL:TRLR y
Port z
Reflect
Executes a OPEN/SHORT reflection calibration on test port z.
:SENS{1-16}:CORR:COLL:TRLR z
Return
Returns to the softkey display screen one level higher.
Line/Match
Displays softkeys for executing LINE/MATCH calibrations. Symbols x, y, and z refer to the three test ports
selected in the
Select Ports
menu (x, y, and z are always 1, 2, and 3 respectively, for models with Option 213 or
214).
x-y
Line/Match
Executes a LINE/MATCH calibration on test ports x and y.
:SENS{1-16}:CORR:COLL:TRLL x,y
:SENS{1-16}:CORR:COLL:TRLL y,x
x-y Fwd(Syx)
Executes a forward LINE/MATCH calibration on test ports x and y.
:SENS{1-16}:CORR:COLL:TRLL y,x
x-y Rvs(Sxy)
Executes a reverse LINE/MATCH calibration on test ports x and y.
:SENS{1-16}:CORR:COLL:TRLL x,y
x-z
Line/Match
Executes a LINE/MATCH calibration on test ports x and z.
:SENS{1-16}:CORR:COLL:TRLL x,z
:SENS{1-16}:CORR:COLL:TRLL z,x
x-z Fwd(Szx)
Executes a forward LINE/MATCH calibration on test ports x and z.
:SENS{1-16}:CORR:COLL:TRLL z,x
x-z Rvs(Sxz)
Executes a reverse LINE/MATCH calibration on test ports x and z.
:SENS{1-16}:CORR:COLL:TRLL x,z
y-z
Line/Match
Executes a LINE/MATCH calibration on test ports y and z.
:SENS{1-16}:CORR:COLL:TRLL y,z
:SENS{1-16}:CORR:COLL:TRLL z,y
y-z Fwd(Szy)
Executes a forward LINE/MATCH calibration on test ports y and z.
:SENS{1-16}:CORR:COLL:TRLL z,y
y-z Rvs(Syz)
Executes a reverse LINE/MATCH calibration on test ports y and z.
:SENS{1-16}:CORR:COLL:TRLL y,z
Return
Returns to the softkey display screen one level higher.
Done
Terminates a calibration process and calculates the calibration
coefficients.
:SENS{1-16}:CORR:COLL:SAVE
Cancel
Displays softkeys for canceling a calibration.
OK
Cancels a calibration process and clears the measurement data of
standard.
:SENS{1-16}:CORR:COLL:CLE
Cancel
Returns to the softkey display screen one level higher.
Return
Returns to the softkey display screen one level higher.
4-Port TRL Cal
Displays softkeys for executing 4-port TRL calibrations.
Thru/Line
Displays softkeys for executing THRU/LINE calibrations.
1-2 Thru/Line
Executes a THRU/LINE calibration for test port 1
→
2.
:SENS{1-16}:CORR:COLL:TRLT 1,2
:SENS{1-16}:CORR:COLL:TRLT 2,1
1-3 Thru/Line
Executes a THRU/LINE calibration for test port 1
→
3.
:SENS{1-16}:CORR:COLL:TRLT 1,3
:SENS{1-16}:CORR:COLL:TRLT 3,1
1-4 Thru/Line
Executes a THRU/LINE calibration for test port 1
→
4.
:SENS{1-16}:CORR:COLL:TRLT 1,4
:SENS{1-16}:CORR:COLL:TRLT 4,1
2-3 Thru/Line
Executes a THRU/LINE calibration for test port 2
→
3.
:SENS{1-16}:CORR:COLL:TRLT 2,3
:SENS{1-16}:CORR:COLL:TRLT 3,2
2-4 Thru/Line
Executes a THRU/LINE calibration for test port 2
→
4.
:SENS{1-16}:CORR:COLL:TRLT 2,4
:SENS{1-16}:CORR:COLL:TRLT 4,2
3-4 Thru/Line
Executes a THRU/LINE calibration for test port 3
→
4.
:SENS{1-16}:CORR:COLL:TRLT 3,4
:SENS{1-16}:CORR:COLL:TRLT 4,3
Return
Returns to the softkey display screen one level higher.
Key Operation
Function
SCPI Command
Summary of Contents for E5070B
Page 6: ......
Page 30: ...24 Contents ...
Page 34: ...28 Chapter1 Precautions Before contacting us ...
Page 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Page 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Page 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Page 634: ...628 AppendixB Troubleshooting Warning Message ...
Page 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Page 740: ...734 AppendixE General Principles of Operation Data Processing ...
Page 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...