![Agilent Technologies E5070B User Manual Download Page 710](http://html.mh-extra.com/html/agilent-technologies/e5070b/e5070b_user-manual_2868065710.webp)
704
Appendix D
Softkey Functions
Measurement Menu (Balanced Measurement, Bal-Bal)
Measurement Menu (Balanced Measurement, Bal-Bal)
Key Operation
Function
SCPI Command
Displays softkeys for setting up measurement parameters (
only for models with Option 412 or 414
). To display
these softkeys, the balanced/unbalanced conversion topology must be set to balanced-balanced (
Bal-Bal
), the
balanced/unbalanced conversion function must be on (
BalUn ON
), and the fixture simulator function must be on
(
Fixture Simulator ON
) in the “Analysis Menu” on page 647.
Sdd11
Selects parameter S
dd11
. S
dd11
defines the way a differential
signal input to (balanced) port 1 on the DUT is reflected as a
differential signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SDD11
Sdd21
Selects parameter S
dd21
. S
dd21
defines the way a differential
signal input to (balanced) port 1 on the DUT is transmitted to
(balanced) port 2 on the DUT as a differential signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SDD21
Sdd12
Selects parameter S
dd12
. S
dd12
defines the way a differential
signal input to (balanced) port 2 on the DUT is transmitted to
(balanced) port 1 on the DUT as a differential signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SDD12
Sdd22
Selects parameter S
dd22
. S
dd22
defines the way a differential
signal input to (balanced) port 2 on the DUT is reflected as a
differential signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SDD22
Scd11
Selects parameter S
cd11
. S
cd11
defines the way a differential signal
input to (balanced) port 1 on the DUT is reflected as a common
mode signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SCD11
Scd21
Selects parameter S
cd21
. S
cd21
defines the way a differential
signal input to (balanced) port 1 on the DUT is transmitted to
(balanced) port 2 on the DUT as a common mode signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SCD21
Scd12
Selects parameter S
cd12
. S
cd12
defines the way a differential
signal input to (balanced) port 2 on the DUT is transmitted to
(balanced) port 1 on the DUT as a common mode signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SCD12
Scd22
Selects parameter S
cd22
. S
cd22
defines the way a differential
signal input to (balanced) port 2 on the DUT is reflected as a
common mode signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SCD22
Sdc11
Selects parameter S
dc11
. S
dc11
defines the way a common mode
signal input to (balanced) port 1 on the DUT is reflected as a
differential signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SDC11
Sdc21
Selects parameter S
dc21
. S
dc21
defines the way a common mode
signal input to (balanced) port 1 on the DUT is transmitted to
(balanced) port 2 on the DUT as a differential signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SDC21
Sdc12
Selects parameter S
dc12
. S
dc12
defines the way a common mode
signal input to (balanced) port 2 on the DUT is transmitted to
(balanced) port 1 on the DUT as a differential signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SDC12
Sdc22
Selects parameter S
dc22
. S
dc22
defines the way a common mode
signal input to (balanced) port 2 on the DUT is reflected as a
differential signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SDC22
Scc11
Selects parameter S
cc11
. S
cc11
defines the way a common mode
signal input to (balanced) port 1 on the DUT is reflected as a
common mode signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SCC11
Scc21
Selects parameter S
cc21
. S
cc21
defines the way a common mode
signal input to (balanced) port 1 on the DUT is transmitted to
(balanced) port 2 on the DUT as a common mode signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SCC21
Scc12
Selects parameter S
cc12
. S
cc12
defines the way a common mode
signal input to (balanced) port 2 on the DUT is transmitted to
(balanced) port 1 on the DUT as a common mode signal.
:CALC{1-16}:FSIM:BAL:PAR{1-16}:BBAL
SCC12
Summary of Contents for E5070B
Page 6: ......
Page 30: ...24 Contents ...
Page 34: ...28 Chapter1 Precautions Before contacting us ...
Page 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Page 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Page 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Page 634: ...628 AppendixB Troubleshooting Warning Message ...
Page 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Page 740: ...734 AppendixE General Principles of Operation Data Processing ...
Page 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...