![Agilent Technologies E5070B User Manual Download Page 658](http://html.mh-extra.com/html/agilent-technologies/e5070b/e5070b_user-manual_2868065658.webp)
652
Appendix D
Softkey Functions
Analysis Menu
(Continued)
Fixture Simulator
De-Embedding
Displays softkeys for setting up the network de-embedding function. Network de-embedding is a function used to
eliminate any user-defined network (with a reference impedance of 50 W) supplied in a 2-port Touchstone data
file, from desired test ports to extend the calibration plane.
De-Embedding
Enables or disables the network de-embedding function.
:CALC{1-16}:FSIM:SEND:DEEM:STA
T
Select Port
Displays softkeys for selecting test ports for which network de-embedding will be performed.
1
Selects test port 1 for performing network de-embedding.
:CALC{1-16}:FSIM:SEND:DEEM:
PORT1
2
Selects test port 2 for performing network de-embedding.
:CALC{1-16}:FSIM:SEND:DEEM:
PORT2
Selects test port 3 for performing network de-embedding.
:CALC{1-16}:FSIM:SEND:DEEM:
PORT3
Selects test port 4 for performing network de-embedding.
:CALC{1-16}:FSIM:SEND:DEEM:
PORT4
Cancel
Returns to the softkey display screen one level higher.
Select Type
Displays softkeys for selecting the type of network de-embedding to be performed on the test port selected in the
Select Port
menu.
None
Does not allow network de-embedding on the test port selected in the
Select
Port
menu.
:CALC{1-16}:FSIM:SEND:DEEM:
PORT{1-4} NONE
User
De-embeds a user-defined network from the test port selected in the
Select
Port
menu. The user-defined network should be prepared in the 2-port
Touchstone data format and loaded onto the E5070B/E5071B from the
User
File
menu.
:CALC{1-16}:FSIM:SEND:DEEM:
PORT{1-4} USER
Cancel
Returns to the softkey display screen one level higher.
User File
Opens a dialog box for reading a 2-port Touchstone data file prepared by
the user. Selecting
User
in the
Select Type
menu will de-embed the loaded
network.
:CALC{1-16}:FSIM:SEND:DEEM:
PORT{1-4}:USER:FIL
Return
Returns to the softkey display screen one level higher.
Diff Matching
Displays softkeys for setting up the differential matching circuit function. This function uses internal software to
convert the characteristics of a balanced port to those with an inserted differential matching circuit.
Diff. Matching
Enables or disables the differential matching circuit function.
:CALC{1-16}:FSIM:BAL:DMC:STAT
Select Bal Port
Displays softkeys for selecting a balanced port to which a differential matching circuit will be added.
Selects port 1 on the DUT for adding a differential matching circuit.
:CALC{1-16}:FSIM:BAL:DMC:BPOR1
2
Selects port 2 on the DUT for adding a differential matching circuit.
:CALC{1-16}:FSIM:BAL:DMC:
BPOR{1-2}
Selects port 3 on the DUT for adding a differential matching circuit.
:CALC{1-16}:FSIM:BAL:DMC:BPOR1
Cancel
Returns to the softkey display screen one level higher.
Select Circuit
Displays softkeys for selecting the type of differential matching circuit.
None
Does not allow a differential matching circuit to be added to the balanced
port selected in the
Select Bal Port
menu.
:CALC{1-16}:FSIM:BAL:DMC:
BPOR{1-2} NONE
ShuntL -
ShuntC
Adds a shunt L - shunt C type differential matching circuit to the port
selected in the
Select Bal Port
menu.
:CALC{1-16}:FSIM:BAL:DMC:
BPOR{1-2} PLPC
User
Adds a user-defined differential matching circuit to the port selected in the
Select Bal Port
menu. The user-defined differential matching circuit should
be provided in the 2-port Touchstone data format and loaded onto the
E5070B/E5071B from the
User File
menu.
:CALC{1-16}:FSIM:BAL:DMC:
BPOR{1-2} USER
Cancel
Returns to the softkey display screen one level higher.
Key Operation
Function
SCPI Command
Summary of Contents for E5070B
Page 6: ......
Page 30: ...24 Contents ...
Page 34: ...28 Chapter1 Precautions Before contacting us ...
Page 286: ...280 Chapter6 Data Analysis Using the Equation Editor ...
Page 430: ...424 Chapter12 Optimizing Measurements Performing a Segment by Segment Sweep segment sweep ...
Page 538: ...532 Chapter15 Measurement Examples Executing Power Calibration ...
Page 634: ...628 AppendixB Troubleshooting Warning Message ...
Page 732: ...726 AppendixD Softkey Functions Trigger Menu ...
Page 740: ...734 AppendixE General Principles of Operation Data Processing ...
Page 760: ...754 AppendixF Replacing the 8753ES with the E5070B E5071B Comparing Functions ...