154 AI4 SIGNAL RANGE 567 (2.2.43, 2.2.5.3)
See ID143.
155 AI4 CUSTOM SETTING MINIMUM 67 (2.2.5.3, 2.2.5.4)
156 AI4 CUSTOM SETTING MAXIMUM * 67 (2.2.5.4, 2.2.5.5)
See IDs 144 and 145.
162 AI4 SIGNAL INVERSION 567 (2.2.44, 2.2.5.5, 2.2.5.6)
See ID151.
164 MOTOR CONTROL MODE 1/2 6 (2.2.7.22)
Contact is open (oc) = Motor control mode 1 is selected
Contact is closed (cc) = Motor control mode 2 is selected
See parameter IDs 600 and 521.
Change from open loop to closed loop control modes and vice versa can only be made in stop
state.
165 AI1 JOYSTICK OFFSET 6 (2.2.2.11)
Define the frequency zero point as follows:
With this parameter on display, place the potentiometer at the assumed zero point and press
Enter on the keypad.
NOTE!
This will not, however, change the reference scaling.
Press Reset button to change the parameter value back to 0.00%.
166 AI2 JOYSTICK OFFSET 6 (2.2.3.11)
See parameter ID165.
167 PID REFERENCE 1 57 (3.4)
The PID controller keypad reference can be set between 0% and 100%. This reference value
is the active PID reference if parameter ID332 = 2.
168 PID REFERENCE 2 57 (3.5)
The PID controller keypad reference 2 can be set between 0% and 100%. This reference is
active if the DIN5 function = 13 and the DIN5 contact is closed.
169 FIELDBUS DIN4 (FBFIXEDCONTROLWORDK, BIT 6) 6 (2.3.3.27)
VACON · 248
PARAMETER DESCRIPTIONS
8
TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205