Table 195: Selections for parameter ID1081
Selection
number
Function
Description
0
Analogue input 1 (AI1)
See ID377
1
Anlogue input 2 (AI2)
See ID388
2
AI1+AI2
3
AI1–AI2
4
AI2–AI1
5
AI1*AI2
6
AI1 joystick
7
AI2 joystick
8
Keypad reference (R3.2)
9
Fieldbus reference
10
Potentiometer reference; con-
trolled with ID418
(TRUE=increase) and ID417
(TRUE=decrease)
11
AI1 or AI2, whichever is lower
12
AI1 or AI2, whichever is greater
13
Max. frequency ID102 (recom-
mended in torque control only)
14
AI1/AI2 selection
See ID422
15
Encoder 1 (AI input C.1)
16
Encoder 2 (With OPTA7 Speed
Synchronization, NXP only AI
input C.3)
17
Master Reference
18
Master Ramp Out (default)
1082 SYSTEMBUS COMMUNICATION FAULT RESPONSE 6 (2.7.30)
Defines the action when SystemBus heartbeat is missing.
VACON · 354