0
ID303
ID304
f
max
ID102
f
out
AI
max.
f
min
ID101
Fig. 35: Reference invert
306 REFERENCE FILTER TIME 2 (2.2.7)
Filters out disturbances from the analogue input signals AI1 and AI2. Long filtering time
makes regulation response slower.
%
100%
63%
t [s]
Filtered signal
Unfiltered signal
ID306
Fig. 36: Reference filtering
307 ANALOGUE OUTPUT FUNCTION (2.16, 2.3.2, 2.3.5.2, 2.3.3.2)
This parameter selects the desired function for the analogue output signal.
VACON · 256