123 KEYPAD DIRECTION (3.3)
Table 108: Selections for parameter ID123
Selection
number
Selection name
Description
0
Forward
The rotation of the motor is forward, when the keypad is the
active control place.
1
Reverse
The rotation of the motor is reversed, when the keypad is the
active control place.
For more information, see the product's User manual.
124 JOGGING SPEED REFERENCE 34567 (2.1.14, 2.1.15, 2.1.19)
Defines the jogging speed reference when activated by digital input. See parameter ID301
and ID413.
The parameter value is automatically limited to Maximum frequency (ID102).
125 CONTROL PLACE (3.1)
The active control place can be changed with this parameter. For more information, see the
product's User manual.
Pushing the Start button for 3 seconds selects the control keypad as the active control place
and copies the Run status information (Run/Stop, direction and reference).
Table 109: Selections for parameter ID125
Selection
number
Selection name
Description
0
PC Control, (activated by
NCDrive)
1
I/O terminal
2
Keypad
3
Fieldbus
126 PRESET SPEED 3 46 (2.1.17)
127 PRESET SPEED 4 46 (2.1.18)
128 PRESET SPEED 5 46 (2.1.19)
129 PRESET SPEED 6 46 (2.1.20)
VACON · 242
PARAMETER DESCRIPTIONS
8
TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205