The changeover is smooth when the reference of the destination source comes from the
Keypad or an internal motor potentiometer (parameter ID332 [PID Ref.] = 2 or 4, ID343 [I/O B
Ref] = 2 or 4, par. ID121 [Keypad Ref] = 2 or 4 and ID122 [Fieldbus Ref]= 2 or 4.
367 MOTOR POTENTIOMETER MEMORY RESET (FREQUENCY REFERENCE) 3567 (2.2.23, 2.2.28,
2.2.1.3, 2.2.1.16)
Table 141: Selections for parameter ID367
Selection
number
Selection name
Description
0
No reset
1
Memory reset in stop and pow-
erdown
2
Memory reset in powerdown
370 MOTOR POTENTIOMETER MEMORY RESET (PID REFERENCE) 57 (2.2.29, 2.2.1.17)
Table 142: Selections for parameter ID370
Selection
number
Selection name
Description
0
No reset
1
Memory reset in stop and pow-
erdown
2
Memory reset in powerdown
371 PID REFERENCE 2 (PLACE A ADDITIONAL REFERENCE) 7 (2.2.1.4)
If the PID reference 2 enable input function (ID330)= TRUE, this parameter defines which
reference place is selected as PID controller reference.
PARAMETER DESCRIPTIONS
VACON · 283
24-HOUR S358 (0)201 212 575 · EMAIL: [email protected]
8