5.4.3
INPUT SIGNALS
Table 36: Input signals, G2.2
Index
Parameter
Min
Max
Unit
Default
Cust
ID
Description
P2.2.1 **
DIN2 function
0
13
1
319
0 = Not used
1 = External fault
cc
2 = External fault
oc
3 = Run enable
4 = Acc/Dec time
selection
5 = CP: I/O termi-
nal (ID125)
6 = CP: Keypad
(ID125)
7 = CP: Fieldbus
(ID125)
8 = Forward/
Reverse
9 = Jogging fre-
quency (cc)
10 = Fault reset
(cc)
11 = Acc/Dec pro-
hibit (cc)
12 = DC braking
command
13 = Motor pot. UP
(cc)
P2.2.2 **
DIN3 function
0
13
10
301
See above except:
13 = Motor pot.
DOWN (cc)
P2.2.3 **
DIN5 function
0
13
9
330
See above except:
13 = Enable PID
reference 2
VACON · 104