manualshive.com logo in svg
background image

Operating Instructions

Wireless Remote Controller

Model No.

CZ-RWSU3 CZ-RWSU2N 

CZ-RWSC3 

CZ-RWSD2

CZ-RWST3N CZ-RWSL2N CZ-RWSK2

Panasonic Corporation

1006 Kadoma, Kadoma City, Osaka, Japan

Installation Instructions Separately Attached.

English

Before operating the unit, read these operating instructions thoroughly and keep them for future 
reference.

CV6233317755

 

Panasonic Corporation

 

 http://www.panasonic.com

TIMER

OPERATION

STANDBY

1 2 3 4

Front side

Rear side

Содержание CZ-RWSU3

Страница 1: ...nasonic Corporation 1006 Kadoma Kadoma City Osaka Japan Installation Instructions Separately Attached English Before operating the unit read these operating instructions thoroughly and keep them for f...

Страница 2: ...ARNING Do not use this appliance in a potentially explosive atmosphere Do not operate with wet hands Do not wash with water In case of malfunction of this appliance do not repair by yourself Contact t...

Страница 3: ...interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televisi...

Страница 4: ...ng the Wind Direction 16 8 Operating Multiple In Outdoor Units Simultaneously 17 9 Using the Remote Controller 18 10 For Best Results 18 11 Addresses 19 12 Emergency Operation 21 13 Miscellaneous Sett...

Страница 5: ...for Use Do not touch switches with wet hands Electric shock and damage to the system can result Protect the remote controller from water because it may cause damage to the system Stop the system and t...

Страница 6: ...2 Names and Operations 6 EN REMOTE CONTROLLER 1 2 3 4 5 6 7 8 9 10 12 11 13 14 15 16...

Страница 7: ...perature setting buttons raises the temperature setting 1 C at a time lowers the temperature setting 1 C at a time 11 Filter button CZ RWSC3 Press to turn off the filter lamp on the receiver 12 Mode S...

Страница 8: ...RWSU3 1 2 3 4 5 1 2 345 1 2 3 4 5 6 ADDRESS 1 ADDRESS 2 ADDRESS 3 REM SUB MAIN 1 2 3 4 7 CZ RWSC3 Front side Rear side CZ RWSL2N 3 4 5 1 2 7 Operation Panel TIMER OPERATION STANDBY 1 2 1 2 2 3 3 4 4 5...

Страница 9: ...when an error occurs 6 FILTER lamp This lamp is for notifying you when the filter needs to be cleaned 7 Address switch See 11 Addresses Note If non cooling heating free type is being used it will bee...

Страница 10: ...controller will not be used for a long period of time remove the batteries Please dispose of batteries appropriately After changing the batteries follow the procedures on the next page to reset the c...

Страница 11: ...2 Set the hour with of the If you press and hold the button the time changes quickly 3 Set the minutes with of the If you press and hold the button the time changes quickly 4 Pressing completes the ti...

Страница 12: ...oes not work in Fan mode 4 Press one of the buttons and set the desired temperature Temperature settings cannot be made in Fan mode MAX C MIN C Auto 27 17 Heat 30 16 Dry Cool 30 18 Stop Press When the...

Страница 13: ...cally via the differences between the set temperature and the room temperature Dry operation Depending on the indoor unit used the remote controller may have a Dry indicator on its display even though...

Страница 14: ...p the unit Using the Timer 1 Press either of the or and while the time is being displayed if you press again a scheduled time can be set The time last set on the timer is displayed indicates time to c...

Страница 15: ...e timer setting is displayed press for the timer again Canceling a timer setting If you press CANCEL the timer setting is canceled If you wish to cancel the setting for either the or the timer press a...

Страница 16: ...facing position and then press again is displayed and the flap swings automatically up and down Stopping Flap Swing If you press again while the flap is swinging you can stop the flap from swinging a...

Страница 17: ...g Ceiling Models Wall Mounted Models Please refer to Setting the Wind Direction and Stopping Flap Swing 8 Operating Multiple In Outdoor Units Simultaneously Group control works well for providing air...

Страница 18: ...may not be received in rooms with rapid start fluorescent lighting inverter lights plasma displays LCD televisions monitor etc For more information please contact the distributor where the product wa...

Страница 19: ...tings are saved in nonvolatile memory in the remote controller so even when its batteries are changed the settings do not have to be made again 1 CZ RWSD2N CZ RWST3N is of receivers inside the indoor...

Страница 20: ...longer When you do this the lamps of the display will blink one after another 3 Press on the remote controller 4 The buzzer will sound and the address of the indoor unit will change to the address dis...

Страница 21: ...is of its front panel CZ RWSU3 CZ RWSU2N CZ RWSD2 Indoor Unit CZ RWSK2 CZ RWST3N CZ RWSL2 CZ RWSC3 Start press Emergency Operation of the receiver If the indoor temperature is 24 C or greater when th...

Страница 22: ...is stopped and then make any desired settings How to Operate While holding down the buttons below the remote controller s display changes every time is pressed Whatever is being displayed when you rel...

Страница 23: ...een set to repeat Check the timer settings See page 14 is displayed on the remote controller when the unit is stopped An error has occurred in the non volatile memory Please contact your sales outlet...

Страница 24: ...8mm D CZ RWSU2N 200 mm H X 200 mm W X 25 mm D CZ RWSD2 65 mm H X 130 mm W X 22 mm D CZ RWSC3 120 mm H X 70 mm W X 20 mm D CZ RWST3N 65 mm H X 141 mm W X 22 5 mm D Power source 16 V DC Supplied from t...