I-7045  

16 Channel Digital Output Data Acquisition 

Module 

Quick Start Guide 

Product Website:  

https://www.icpdas-usa.com/i_7045_i_7045d.html

 

http://www.icpdas-usa.com/dcon_utility_pro.html

  

1. Introduction 

 

I-7045 is intelligently designed to provide signal conditioning system 
monitoring and safe value settings. I-7045 is a cost-effective solution for a 
wide range of valuable industrial control signals and systems. The DCON 
utility can help users to configure and test I-7045 16-Channel Isolated 
Digital Output modules. Plenty of library functions and demo programs are 
provided to let users develop programs easily under Windows, Linux and 
DOS operating systems. Users may mount the modules on a DIN rail, 
panel or wall. Modules have a screw-terminal block to connect to the 
signals. 
 

2. Terminal Assignment 

 

Summary of Contents for I-7045

Page 1: ...signed to provide signal conditioning system monitoring and safe value settings I 7045 is a cost effective solution for a wide range of valuable industrial control signals and systems The DCON utility can help users to configure and test I 7045 16 Channel Isolated Digital Output modules Plenty of library functions and demo programs are provided to let users develop programs easily under Windows Li...

Page 2: ...I 7045 16 Ch DO DAQ Module QuickStart May 2017 ICP DAS USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 2 3 Block Wiring Diagram ...

Page 3: ...um disabled J3 set to INIT mode enabled for I 7043 43D and M 7043 43D 5 Configuration To install the module follow the steps below 1 Connect the analog output 2 Connect the module to the RS 485 network using the DATA and DATA terminals If the host is only equipped with an RS 232 interface then an RS 232 to RS 485 converter will be required 3 Connect the module to the power supply using the Vs and ...

Page 4: ...24309 Narbonne Ave Suite 200 Lomita CA 90717 4 4 Open DCON utility pro click on COM port first icon It can select multi options such as Baud Rate Protocol Checksum and Format to search module The default settings for the module can be found in Section 3 Click OK after selecting the COM port setting ...

Page 5: ... www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 5 5 DCON utility pro will search for the selected COM port according the setting previously set DCON Utility Pro supports DCON and Modbus protocol for all ICPDAS and the others modules ...

Page 6: ... USA Inc www icpdas usa com 1 310 517 9888 24309 Narbonne Ave Suite 200 Lomita CA 90717 6 6 Configuration I O module setting on PC 7 For I 7000 modules DCON utility pro terminal can send command to the module See user manual Sections 2 for details command ...

Page 7: ...717 7 Configure the module sending the AANNTTCCFF command See user manual Section 2 for details Read data from the input channels send either the AA or AAN command to the module 8 If user doesn t know command user can select Address and ID it will show some refer commands as below User can select necessary command to test or debug modules ...

Reviews: