Parameter
List of parameters
1-202
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Displays the effective negative speed limit.
Dependency:
Refer to: p1082, p1086, p1088
Description:
Sets the signal source for the speed/velocity limit of the negative direction.
Description:
Sets skip speed 1.
Dependency:
Refer to: p1092, p1093, p1094, p1101
Notice:
Skip bandwidths can also become ineffective as a result of the downstream limits in the setpoint channel.
Note:
The skip (suppression) speeds can be used to prevent the effects of mechanical resonance.
Description:
Sets skip speed 2.
Dependency:
Refer to: p1091, p1093, p1094, p1101
Notice:
Skip bandwidths can also become ineffective as a result of the downstream limits in the setpoint channel.
r1087
CO: Speed limit negative effective / n_limit neg eff
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
3050, 3095
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
- [rpm]
- [rpm]
- [rpm]
p1088[0...n]
CI: Speed limit in negative direction of rotation / n_limit neg
SERVO_S110-CAN
(Extended set),
SERVO_S110-DP
(Extended set),
SERVO_S110-PN
(Extended set)
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
CDS, p0170
Func. diagram:
3050
P-Group:
Setpoints
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
- -
1086[0]
p1091[0...n]
Skip speed 1 / n_skip 1
SERVO_S110-CAN
(Extended set),
SERVO_S110-DP
(Extended set),
SERVO_S110-PN
(Extended set)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
3050
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
0.000 [rpm]
210000.000 [rpm]
0.000 [rpm]
p1092[0...n]
Skip speed 2 / n_skip 2
SERVO_S110-CAN
(Extended set),
SERVO_S110-DP
(Extended set),
SERVO_S110-PN
(Extended set)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
3050
P-Group:
Setpoints
Units group:
3_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
0.000 [rpm]
210000.000 [rpm]
0.000 [rpm]