Parameter
List of parameters
1-478
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
--> p5009 = 51 ... 53: fault values if the operation was not able to be successfully completed.
--> carry out a POWER ON (switch-off/switch-on).
Value:
0:
No function
1:
Reset
2:
Set invalid
3:
Reserved
5:
Set valid
20:
Operation successfully completed.
40:
Operation running
51:
Function not supported
52:
File access unsuccessful
53:
Operation unsuccessful
Note:
Help for fault value = 51 ... 53:
- repeat the operation.
Description:
Setting to enable/inhibit spindle commissioning.
Value:
0:
Spindle commissioning enabled
1:
Spindle commissioning inhibited
Note:
The parameter is automatically set to a value of 1 after exiting commissioning (p0009 = 0).
Description:
Displays the status for write protection of adjustable parameters.
Note:
Write protection can be activated/deactivated via p7760 on the Control Unit.
Description:
Setting for activating/de-activating the write protection for adjustable parameters.
Value:
0:
Inactive
1:
Active
Note:
The following parameters are excluded from the write protection:
- p0003 (BOP access level)
- p0971 (drive object save parameters)
- p0977 (save all parameters)
- p3950 (service parameters)
p5016
Enable spindle commissioning / Enable comm
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
r7760
Write protection status / Write prot stat
All objects
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Write protection active
-
p7761
Write protection / Write protection
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0