Parameter
List of parameters
1-450
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Caution:
If the selected subdirectory contains a number of data sets, "More Datasets" is displayed in r4694[0...19].
If there is no SMI data (motor/encoder data) in the selected subdirectory or if the selected subdirectory does not
exist, the following applies:
- The number of the next subdirectory located is displayed.
- This subdirectory is not checked for valid SMI data.
- If another subdirectory cannot be located, nothing is displayed in r4694[0...19].
Note:
SMI: SINAMICS Sensor Module Integrated
Description:
Setting to control the trace function.
Value:
0:
Stop trace
1:
Start trace
Index:
[0] = Trace 0
[1] = Trace 1
Description:
Setting to control the measurement function.
Value:
0:
Stop measuring function
1:
Start measuring function
2:
Measuring function, check parameterization
3:
Start measuring function without enable signals
Description:
Displays the actual status of the trace.
Value:
0:
Trace inactive
1:
Trace is recording presamples
2:
Trace is waiting for trigger event
3:
Trace is recording
4:
Recording (trace) ended
Index:
[0] = Trace 0
[1] = Trace 1
p4700[0...1]
Trace control / Trace control
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0 1
0
p4701
Measuring function, control / Meas fct ctrl
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0 3
0
r4705[0...1]
Trace status / Trace status
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0 4
-
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......