Parameter
List of parameters
1-578
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the SLS-specific stop response for the function "Safely-Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
In the case of encoderless motion monitoring (p9506/p9306 = 1), only a value of 0 or 1 is permitted.
Value:
0:
STOP A
1:
STOP B
2:
STOP C
3:
STOP D
4:
STOP E
10:
STOP A with delayed pulse suppression when the bus fails
11:
STOP B with delayed pulse suppression when the bus fails
12:
STOP C with delayed pulse suppression when the bus fails
13:
STOP D with delayed pulse suppression when the bus fails
14:
STOP E with delayed pulse suppression when the bus fails
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLP4
Dependency:
Refer to: p9531, p9561, p9580
Note:
The values 4 and 14 are not supported on Control Unit 305.
SLS: Safely-Limited Speed
Description:
Sets the tolerance for the function "Safe motion direction" (SDI). This motion in the monitored direction is still per-
missible before an alarm is initiated.
Dependency:
Refer to: p9565, p9566
Refer to: C01716
Note:
SDI: Safe Direction (safe motion direction)
Description:
Sets the tolerance for the function "Safe motion direction" (SDI). This motion in the monitored direction is still per-
missible before an alarm is initiated.
Dependency:
Refer to: p9565, p9566
Refer to: C01716
Note:
SDI: Safe Direction (safe motion direction)
p9563[0...3]
SI Motion SLS-specific stop response (processor 1) / SI Mtn SLS stop P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 14
2
p9564
SI Motion SDI tolerance (processor 1) / SI Mtn SDI tol P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2861
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.001 [mm]
360.000 [mm]
12.000 [mm]
p9564
SI Motion SDI tolerance (processor 1) / SI Mtn SDI tol P1
SERVO_S110-CAN
(Safety rot),
SERVO_S110-DP
(Safety rot),
SERVO_S110-PN
(Safety rot)
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2861
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.001 [°]
360.000 [°]
12.000 [°]