Parameter
List of parameters
1-608
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the transition period from STOP F to STOP A on processor 2.
Dependency:
Refer to: p9658, r9895
Refer to: F30611
Notice:
This parameter is overwritten by the copy function of the safety functions integrated in the drive.
Note:
For a crosswise data comparison between p9658 and p9858, a difference of one Safety monitoring clock cycle is
tolerated.
The parameterized time is rounded internally to an integer multiple of the monitoring clock cycle.
STOP F: Defect in a monitoring channel (error in the crosswise data comparison)
STOP A: Pulse suppression via the safety shutdown path
Description:
Displays the Safety Integrated monitoring functions supported on processor 1 and processor 2.
Processor 2 determines this display.
Dependency:
Refer to: r9771
Note:
MM: Motor Module
SBC: Safe Brake Control
SDI: Safe Direction (safe motion direction)
SI: Safety Integrated
SS1: Safe Stop 1
STO: Safe Torque Off / SH: Safe standstill
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring) / SGA n < nx: Safety-
related output n < nx
ESR: Extended Stop and Retract
p9858
SI transition time STOP F to STOP A (processor 2) / SI STOP F->A P2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2802
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [µs]
30000000.00 [µs]
0.00 [µs]
r9871
SI common functions (processor 2) / SI common fct P2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2804
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO supported via terminals
Yes
No
2804
01
SBC supported
Yes
No
2804
02
Extended Functions supported (p9501 > 0)
Yes
No
2804
03
SS1 supported
Yes
No
2804
04
Extended Functions PROFIsafe supported
Yes
No
-
05
Extended Functions integrated in drive sup-
ported (p9601.2 = 1)
Yes
No
-
06
Basic Functions PROFIsafe supported
Yes
No
-
07
Extended Functions encoderless supported Yes
No
-
08
Safe Brake Adapter supported
Yes
No
-
09
Basic Functions PROFIsafe for parallel con-
nection supported
Yes
No
-
10
Extended Functions integrated in drive for
parallel connection
Yes
No
-
11
Extended Functions SDI supported
Yes
No
-
12
Extended Functions SSM encoderless sup-
ported