Te
ch
no
lo
gy
co
nt
ro
ller
Fu
nction dia
g
ra
ms
2-
93
5
© Siemens AG 2
012 All Rights Reserved
SINAMICS
S110 List Manual (L
H7)
, 06/
2012
, 6SL3097-
4AP10-0BP3
Fi
g. 2
-1
65
795
1
–
Fixe
d va
lues,
direct
se
lection
(p2
216
=
1
)
- 7951 -
Function diagram
8
7
6
5
4
3
2
1
fp_7951_98_eng.vsd
DO: SERVO
SINAMICS S110
23.09.09 V04.04.00
Technology controller - Fixed value selection direct (p2216 = 1)
<101> The pre-assignment of the sampling time in p0115[6] is 4000.00 μs.
(0)
Tec_ctrl sel bit 0
p2220[C]
(0)
Tec_ctrl sel bit 1
p2221[C]
(0)
Tec_ctrl sel bit 3
p2223[C]
(0)
Tec_ctrl sel bit 2
p2222[C]
<101>
Refer to [1020.7]
p0115[6] (Drive Object)
Tec_ctrl fix val 1
-200.00...200.00 [%]
p2201[D] (10.00)
Tec_ctrl fix val 2
-200.00...200.00 [%]
p2202[D] (20.00)
Tec_ctrl fix val 3
-200.00...200.00 [%]
p2203[D] (30.00)
Tec_ctrl fix val 4
-200.00...200.00 [%]
p2204[D] (40.00)
r2224
Tec_ctr FixVal eff
0 0 0 1
p2201[D]
p2203[D]
p2204[D]
0 1 0 0
p2202[D]
1 0 0 0
+
+
+
+
+
+
r2225
Tec_reg FW Status
0 0 1 0