List of parameters
Parameter
1-719
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the signal source of input quantity X and of setting value SV of instance PT1 0 of the smoothing element.
Index:
[0] = Input X
[1] = Setting value SV
Description:
Sets the signal source for the "accept setting value" signal of instant PT1 0 of the smoothing element.
Description:
Sets the smoothing time constant T in milliseconds of instance PT1 0 of the smoothing element.
Description:
Display parameter for the smoothed output quantity Y of instance PT1 0 of the smoothing element.
p20244[0...1]
CI: PT1 0 inputs / PT1 0 inputs
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / FloatingPoint32
Dynamic index:
-
Func. diagram:
7262
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
0
p20245
BI: PT1 0 accept setting value S / PT1 0 acc set val
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
7262
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p20246
PT1 0 smoothing time constant in ms / PT1 0 T_smooth ms
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
7262
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 340.28235E36
0.00
r20247
CO: PT1 0 output Y / PT1 0 output Y
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN,
SERVO_S110-CAN
(FBLOCKS),
SERVO_S110-DP
(FBLOCKS),
SERVO_S110-PN
(FBLOCKS)
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
7262
P-Group:
-
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......