List of parameters
Parameter
1-603
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Displays the Safety Integrated status on the drive (processor 1 + processor 2).
Note:
This status is formed from the AND operation of the relevant status of the two monitoring channels.
Description:
The parameter is used for diagnostics.
Note:
Re bit 00 = 1:
At least one Safety parameter has been changed that will only take effect after a POWER ON.
Description:
Displays the clock cycle time for the Safety Integrated Basic Functions on the Control Unit.
Dependency:
Refer to: r9880
Description:
Displays the checksum for tracking changes for Safety Integrated.
These are additional checksums that are created to track changes (fingerprint for the "safety logbook" functionality)
to safety parameters (that are relevant for checksums).
r9773.0...31
CO/BO: SI status (processor 1 + processor 2) / SI status P1+P2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2804
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO selected in drive
Yes
No
2804
01
STO active in drive
Yes
No
2804
02
SS1 delay time active in the drive
Yes
No
2804
04
SBC requested
Yes
No
2804
05
SS1 selected in the drive (Basic Functions)
Yes
No
-
06
SS1 active in the drive (Basic Functions)
Yes
No
-
31
Shutdown paths must be tested
Yes
No
2810
r9776
SI diagnostics / SI diagnostics
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
4
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Safety parameter changed POWER ON
required
Yes
No
-
r9780
SI monitoring clock cycle (Control Unit) / SI monitor_clck CU
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2802
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r9781[0...1]
SI checksum to check changes (Control Unit) / SI chg chksm CU
CU_S110-CAN,
CU_S110-DP,
CU_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......