Parameter
List of parameters
1-396
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the mode to evaluate "external block change".
Value:
0:
External block change via the measuring probe
1:
External block change via BI: p2633
Dependency:
Refer to: p2623, p2633, r2677, r2678
Note:
In the mode "external block change via measuring probe (p2632 = 0), the following applies:
When starting a traversing block with the block change enable CONTINUE_EXTERNAL,
CONTINUE_EXTERNAL_WAIT and CONTINUE_EXTERNAL_ALARM an activated "flying referencing" is inter-
rupted. After ending the block, "flying referencing" must be re-activated via BI: p2595 = 0/1 signal.
Description:
Sets the signal source for "external block change".
BI: p2633 = 0/1 signal
Dependency:
The evaluation of the signal is only active p2632 = 1.
Refer to: p2623, p2632, p2640, p2641, r2677, r2678
Notice:
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
A 0/1 edge initiates a flying block change in the subsequent traversing block.
When the external block change is identified, the actual position is saved in r2678.
A traversing task can be influenced using the following signals:
- intermediate stop via BI: p2640.
- reject traversing task via BI: p2641.
Description:
Sets the following error to detect the "fixed stop reached" state (r2526.4).
Dependency:
Refer to: r2526, p2621, r2675
Note:
The state "fixed stop reached" is detected if the following error exceeds the theoretically calculated following error
value by p2634.
p2632
EPOS external block change evaluation / Ext BlckChg eval
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
3615, 3616
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p2633
BI: EPOS external block change (0 -> 1) / Ext BlckChg (0->1)
SERVO_S110-CAN
(EPOS),
SERVO_S110-DP
(EPOS),
SERVO_S110-PN
(EPOS)
Can be changed:
T
Calculated:
-
Access level:
1
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
3615
P-Group:
Basic positioner
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p2634[0...n]
EPOS fixed stop maximum following error / Following err max
SERVO_S110-CAN
(Pos ctrl),
SERVO_S110-DP
(Pos ctrl),
SERVO_S110-PN
(Pos ctrl)
Can be changed:
U, T
Calculated:
-
Access level:
1
Data type:
Unsigned32
Dynamic index:
DDS, p0180
Func. diagram:
3617, 4025
P-Group:
Closed loop position control
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [LU]
2147482647 [LU]