Parameter
List of parameters
1-626
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
3:
F-DI 2
255:
Statically inact
Dependency:
Refer to: p10106
Refer to: A01666, A30666
Note:
F-DI: Failsafe Digital Input
If value = 0:
No terminal assigned, acknowledge input has a static zero value.
Description:
Selects an input terminal to start the test stop.
The test stop is started with a 0/1 signal at the input terminal and is then only possible if the drive is not in commis-
sioning mode.
Dependency:
Refer to: p10001, p10002, p10003, p10040, p10046
Description:
Sets the debounce time for digital inputs.
The debounce time is accepted rounded off to whole milliseconds.
The debounce time acts on the following digital inputs:
- Fail-safe digital inputs (F-DI).
- Single-channel digital inputs (DI).
- Single-channel digital input 22 (DI 22, read back input for the forced checking procedure).
Dependency:
Refer to: p10117
Note:
Example:
Debounce time = 1 ms: Fault pulses of 1 ms are filtered; only pulses longer than 2 ms are processed.
Debounce time = 3 ms: Fault pulses of 3 ms are filtered; only pulses longer than 4 ms are processed.
The debounce result can be read in r10051.
Description:
Sets the fail-safe digital input (F-DI) for the "STO" function.
Value:
0:
Statically active
1:
F-DI 0
2:
F-DI 1
3:
F-DI 2
255:
Statically inact
Dependency:
Refer to: p10122
p10007
BI: SI forced checking procedure F-DO signal source / SI frc_chF-DO s_sc
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dynamic index:
-
Func. diagram:
2848
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p10017
SI digital inputs debounce time (processor 1) / SI DI t_debounceP1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [ms]
100.00 [ms]
0.00 [ms]
p10022
SI STO input terminal (processor 1) / SI STO F-DI P1
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 255
0