List of parameters
Parameter
1-335
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Re bit 03:
The hysteresis is set in p2150.
Re bit 06:
The hysteresis is set in p2162.
Re bit 07:
The threshold value is set in p2163 and the hysteresis is set in p2164.
Description:
Displays the second status word for monitoring functions.
Note:
Re bit 10:
The torque threshold value 1 is set in p2174.
Re bit 12:
This bit is reset after the fault cause disappears, even if the fault itself is still present.
Description:
Displays the third status word for monitoring functions.
Note:
Re bit 00:
The speed threshold value 3 is set in p2161.
Re bit 01:
The comparison value is set in p2141. We recommend setting the hysteresis (p2142) for canceling the bit to a value
lower than that in p2141. Otherwise, the bit will never be reset.
Re bit 11:
The torque threshold value 2 is set in p2194.
r2198.4...12
CO/BO: Status word monitoring 2 / ZSW monitor 2
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2536
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
04
|n_set| < p2161
Yes
No
8010
05
n_set > 0
Yes
No
8010
06
Motor stalled
Yes
No
8012
10
|M_set| < torque threshold value 1
Yes
No
8012
11
Load monitoring signals an alarm
Yes
No
8013
12
Load monitoring signals a fault condition
Yes
No
8013
r2199.0...11
CO/BO: Status word monitoring 3 / ZSW monitor 3
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
1530, 2537
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
|n_act| < speed threshold value 3
Yes
No
8010
01
f or n comparison value reached or
exceeded
Yes
No
8010
04
Speed setp - act val deviation in tolerance
t_on
Yes
No
8010
05
Ramp-up/ramp-down completed
Yes
No
8010
06
Current below the zero current threshold
Yes
No
-
11
Torque utilization < torque threshold value 2 Yes
No
8012