Parameters for data sets
Parameter
1-733
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
1.3
Parameters for data sets
1.3.1
Parameters for command data sets (CDS)
The following list contains the parameters that are dependent on the command data sets.
Product: S110, Version: 4402100, Language: eng, Type: CDS
p0820[0...n]
BI: Drive Data Set selection DDS bit 0 / DDS select., bit 0
p0828[0...n]
BI: Motor changeover, feedback signal / Mot_chng fdbk sig
p0840[0...n]
BI: ON / OFF (OFF1) / ON / OFF (OFF1)
p0844[0...n]
BI: No coast-down / coast-down (OFF2) signal source 1 / OFF2 S_src 1
p0845[0...n]
BI: No coast-down / coast-down (OFF2) signal source 2 / OFF2 S_src 2
p0848[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 1 / OFF3 S_src 1
p0849[0...n]
BI: No Quick Stop / Quick Stop (OFF3) signal source 2 / OFF3 S_src 2
p0852[0...n]
BI: Enable operation/inhibit operation / Operation enable
p0854[0...n]
BI: Control by PLC/no control by PLC / Master ctrl by PLC
p0855[0...n]
BI: Unconditionally release holding brake / Uncond open brake
p0856[0...n]
BI: Speed controller enable / n_ctrl enable
p0858[0...n]
BI: Unconditionally close holding brake / Uncond close brake
p1020[0...n]
BI: Fixed speed setpoint selection Bit 0 / n_set_fixed Bit 0
p1021[0...n]
BI: Fixed speed setpoint selection Bit 1 / n_set_fixed Bit 1
p1022[0...n]
BI: Fixed speed setpoint selection Bit 2 / n_set_fixed Bit 2
p1023[0...n]
BI: Fixed speed setpoint selection Bit 3 / n_set_fixed Bit 3
p1035[0...n]
BI: Motorized potentiometer setpoint raise / Mop raise
p1036[0...n]
BI: Motorized potentiometer lower setpoint / Mop lower
p1039[0...n]
BI: Motorized potentiometer inversion / MotP inv
p1041[0...n]
BI: Motorized potentiometer manual/automatic / Mop manual/auto
p1042[0...n]
CI: Motorized potentiometer automatic setpoint / Mop auto setpoint
p1043[0...n]
BI: Motorized potentiometer accept setting value / MotP acc set val
p1044[0...n]
CI: Motorized potentiometer setting value / Mop set val
p1051[0...n]
CI: Speed limit RFG positive direction of rotation / n_limit RFG pos
p1052[0...n]
CI: Speed limit RFG negative direction of rotation / n_limit RFG neg
p1055[0...n]
BI: Jog bit 0 / Jog bit 0
p1056[0...n]
BI: Jog bit 1 / Jog bit 1
p1070[0...n]
CI: Main setpoint / Main setpoint
p1071[0...n]
CI: Main setpoint scaling / Main setp scal
p1075[0...n]
CI: Suppl setpoint / Suppl setpoint
p1076[0...n]
CI: Supplementary setpoint scaling / Suppl setp scal
p1085[0...n]
CI: Speed limit in positive direction of rotation / n_limit pos
p1088[0...n]
CI: Speed limit in negative direction of rotation / n_limit neg
p1110[0...n]
BI: Inhibit negative direction / Inhib neg dir
p1111[0...n]
BI: Inhibit positive direction / Inhib pos dir
p1113[0...n]
BI: Setpoint inversion / Setp inv
p1122[0...n]
BI: Bypass ramp-function generator / Bypass RFG
p1140[0...n]
BI: Enable ramp-function generator/inhibit ramp-function generator / RFG enable
Note:
References: /FH3/
SINAMICS S110 Function Manual
Chapter "Data sets"