Parameter
List of parameters
1-592
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Note:
This parameter is only supplied with actual values in the case of Safety Integrated Extended Functions. For Safety
Integrated Basic Functions (SBC, SS1, STO), the value is equal to zero.
Description:
Status signal for safety-relevant motion monitoring functions integrated in the drive.
Notice:
Re bit 07:
The signal state behaves in an opposite way to the PROFIsafe Standard.
Note:
This parameter is only supplied with actual values in the case of Safety Integrated Extended Functions. For Safety
Integrated Basic Functions (SBC, SS1, STO), the value is equal to zero.
Re bit 07:
An internal event is displayed if a STOP A ... F is active.
Description:
Displays the diagnostic signals for safety-relevant motion monitoring functions integrated in the drive.
Note:
ESR: Extended Stop and Retract
SAM: Safe Acceleration Monitor (safe acceleration monitoring)
SBR: Safe Brake Ramp (safe brake ramp monitoring)
r9722.0...15
CO/BO: SI Motion status signals integrated in the drive / SI Mtn integ stat
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2840, 2855
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
STO active
Yes
No
-
01
SS1 active
Yes
No
-
02
SS2 active
Yes
No
-
03
SOS active
Yes
No
-
04
SLS active
Yes
No
-
07
Internal event
No
Yes
-
09
Active SLS stage bit 0
Set
Not set
-
10
Active SLS stage bit 1
Set
Not set
-
11
SOS selected
Yes
No
-
12
SDI pos active
Yes
No
2861
13
SDI neg active
Yes
No
2861
15
SSM (speed below limit value)
Yes
No
2860
r9723.0...16
CO/BO: SI Motion diagnostic signals integrated in the drive / SI Mtn integ diag
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Forced checking procedure required
Yes
No
-
01
For ESR, STOP F and subsequent stop B is
active
Yes
No
-
02
Communication failure
Yes
No
-
03
Actual value sensing supplies valid value
Yes
No
-
04
Encoderless act val sensing acc to tech-
nique for U/f control
Yes
No
-
16
SAM/SBR active
Yes
No
-
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......