List of parameters
Parameter
1-577
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency:
Refer to: p9556
Description:
Sets the shutdown speed for the pulse suppression.
Below this speed "standstill" is assumed and for STOP B, the pulses are suppressed by changing to STOP A).
Dependency:
Refer to: p9556
Description:
Sets the stop response for the function "Safely-Limited Speed" (SLS).
This setting applies for all SLS limit values.
An input value of less than 5 signifies personnel protection, from 10 and upwards, machine protection.
This parameter can only be used for ncSI nutzbar, not for dbSI1/2. For motion monitoring functions integrated in the
drive (dbSI1/2) only the value 5 is permissible; all other settings result in fault F01711 or F30711 with fault value 44.
Value:
0:
STOP A
1:
STOP B
2:
STOP C
3:
STOP D
4:
STOP E
5:
Sets the stop response via p9563 (SLS-specific)
10:
STOP A with delayed pulse suppression when the bus fails
11:
STOP B with delayed pulse suppression when the bus fails
12:
STOP C with delayed pulse suppression when the bus fails
13:
STOP D with delayed pulse suppression when the bus fails
14:
STOP E with delayed pulse suppression when the bus fails
Dependency:
Refer to: p9531, p9563, p9580
Note:
SLS: Safely-Limited Speed
Description:
Sets the stop response for the function "Safely-Limited Position" (SLP).
Value:
2:
STOP C
3:
STOP D
4:
STOP E
Dependency:
Refer to: p9534, p9535
Note:
SLP: Safely-Limited Position
p9560
SI Motion pulse suppression shutdown speed (Control Unit) / SI Mtn IL n_shutCU
SERVO_S110-CAN
(Safety rot),
SERVO_S110-DP
(Safety rot),
SERVO_S110-PN
(Safety rot)
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [rpm]
6000.00 [rpm]
0.00 [rpm]
p9561
SI Motion SLS stop response (processor 1) / SI Mtn SLS resp
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 14
5
p9562
SI Motion SLP stop response (processor 1) / SI Mtn SLP resp
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
4
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
2 4
2
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......