List of parameters
Parameter
1-231
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the proportional gain for the DC-link voltage controller (Vdc_min controller, Vdc_max controller).
Dependency:
Refer to: p1240, p1244, p1248
Description:
Sets the control word for the motor holding brake.
Description:
Sets the delay time for closing the brake at standstill.
After this time has expired, if the "close brake at standstill" or OFF1/OFF3 is present, the brake is closed and the
pulses are suppressed.
For p1276 = 300.000 s, the timer is de-activated - this means that the timer output is always zero.
Description:
Sets the delay time for the signal "braking threshold exceeded" (BO: r1229.6).
Dependency:
Refer to: p1220, p1221, r1229
p1250[0...n]
Vdc controller proportional gain / Vdc_ctrl Kp
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
CALC_MOD_CON
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
5650
P-Group:
Functions
Units group:
19_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [A/V]
10.00 [A/V]
1.00 [A/V]
p1275
Motor holding brake control word / Brake STW
SERVO_S110-CAN
(Extended brk),
SERVO_S110-DP
(Extended brk),
SERVO_S110-PN
(Extended brk)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
-
-
0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Inverting BI: 1219[0]
Yes
No
2707
01
Inverting BI: 1219[1]
Yes
No
2707
02
Inverting BI: 1224[0]
Yes
No
2704
03
Inverting BI: 1224[1]
Yes
No
2704
05
Brake with feedback
Yes
No
2711
p1276
Motor holding brake, standstill detection, bypass / Brk standst bypass
SERVO_S110-CAN
(Extended brk),
SERVO_S110-DP
(Extended brk),
SERVO_S110-PN
(Extended brk)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2704
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
300.000 [s]
300.000 [s]
p1277
Motor holding brake, braking threshold delay exceeded / Del thresh exceed.
SERVO_S110-CAN
(Extended brk),
SERVO_S110-DP
(Extended brk),
SERVO_S110-PN
(Extended brk)
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
2707
P-Group:
Functions
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 [s]
300.000 [s]