Function diagram
8
7
6
5
4
3
2
1
fp_1021_98_eng.vsd
DO: All objects
SINAMICS S110
25.05.08 V04.04.00
Explanations for the function diagrams - Explanation of the symbols (Part 2)
Symbols for logic functions
Pre-assigned binectors and connectors
Logical inversion
AND element
with logical inversion
of an input signal
Symbols for computational and closed-loop
control functions
Sign reversal
y = -x
Absolute value generator
y = |x|
Divider
y =
2
1
x
x
Comparator
Output y = a logical "1", if the analog
signal x > 0, i.e. is positive.
Threshold value switch 1/0
Outputs at y a logical "1" if x < S.
Simple changeover switch
The switch position is shown according to
the factory setting
(in this case, switch position 1 in the
default state on delivery).
Limiter
x is limited to the upper limit LU and the lower
limit LL and output at y.
The digital signals MLU and MLL have the
value "1", if the upper or lower limit is active.
1
&
R/S flip-flop
S = setting input
R = reset input
Q = non-inverted output
= inverted output
Q
x
y
x
y
>0
-1
x
y
x
2
x
1
y
S Q
R Q
p2900[D]
Fixed value 1
p2901[D]
Fixed value 2
-10 000.00...10 000.00 [%]
p2900[D] (0.00)
-10 000.00...10 000.00 [%]
p2901[D] (0.00)
Fixed percentage values
S
y
x
1
0
Threshold value switch 0/1
Outputs at y a logical "1" if x > S.
0
1
y
x
S
Symbols for computational and
closed-loop control functions
Differentiator
y =
dt
dx
Sample & Hold element
Sample and hold element.
y = x if SET = 1
(not retentively saved at POWER OFF)
1
0
pxxxx
LU
LL
MLL
MLU
x
y
Fixed speed values
-210 000.000...210 000.000 [1/min]
p1001[D] (0.000)
p1001[D]
n_set_fixed 1
-210 000.000...210 000.000 [1/min]
p1015[D] (0.000)
p1015[D]
n_set_fixed 15
Fixed torque values
-100 000.00...100 000.00 [Nm]
p2930[D] (0.00)
p2930[D]
Fixed value M [Nm]
dx
dt
x
y
Pre-assigned binectors and connectors
Pre-assigned binectors and connectors
Switch symbol
Threshold value 1/0 with
hysteresis
Outputs a logical "1" at y if x < S.
If x >= S + H then y returns to 0.
0
1
S
H
y
x
Threshold value 0/1 with
hysteresis
Outputs a logical "1" at y if x > S.
If x <= S - H then y returns to 0.
0
1
H
S
y
x
r2902[0...14]
[8] = Fixed value -5 %
[9] = Fixed value -10 %
[10] = Fixed value -20 %
[11] = Fixed value -50 %
[12] = Fixed value -100 %
[13] = Fixed value -150 %
[14] = Fixed value -200 %
r2902[0...14] (0.00)
SET
S & H
x
y
Monitoring
Axxxxx
or
Fxxxxx
Symbol for monitoring
Monitoring
In the bottom right-hand corner of
the diagram.
Exclusiv-OR/XOR
y = 1 for x
1
x
2
=1
x
1
y
x