Parameter
List of parameters
1-600
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Dependency:
Refer to: r9744, r9747, r9748, r9749, p9752, r9753, r9755, r9756
Description:
Displays the relative system runtime in milliseconds when the safety message was removed.
Dependency:
Refer to: r9744, r9747, r9748, r9749, p9752, r9753, r9754, r9756
Description:
Displays the relative system runtime in days when the safety message was removed.
Dependency:
Refer to: r9744, r9747, r9748, r9749, p9752, r9753, r9754, r9755
Description:
Enters the Safety Integrated password.
Dependency:
Refer to: F01659
Note:
It is not possible to change Safety Integrated parameters until the Safety Integrated password has been entered.
Description:
Enters a new Safety Integrated password.
Dependency:
A change made to the Safety Integrated password must be acknowledged in the following parameter:
Refer to: p9763
Description:
Acknowledges the new Safety Integrated password.
r9755[0...63]
SI message time removed in milliseconds / SI t_msg rem ms
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r9756[0...63]
SI message time removed in days / SI t_msg rem days
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
-
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
p9761
SI password input / SI password inp
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C1, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2800
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p9762
SI password new / SI password new
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2800
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p9763
SI password acknowledgement / SI ackn password
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(95)
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2800
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex