SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Note:
The value depends on the device type and the selected rated voltage p0210.
For booksize units, the following applies:
The undervoltage threshold can be reduced with p0278.
Description:
If the DC link voltage exceeds the threshold specified here, the drive unit is tripped due to DC link overvoltage.
Dependency:
Refer to: F30002
Description:
Selects the motor type or start to read in the motor parameters for a motor with DRIVE-CLiQ (p0300 = 10000).
For p0300 < 10000 the following applies:
The first digit of the parameter value always defines the general motor type and corresponds to the third-party
motor belonging to a motor list:
1 = Rotating induction motor
2 = Rotating synchronous motor
The type information must be entered to filter motor-specific parameters and to optimize the operating characteris-
tics and behavior. For example, for synchronous motors, power factor (p0308) is neither used nor displayed (in the
BOP/AOP).
Value:
0:
No motor
1:
Induction motor (rotating)
2:
Synchronous motor (rotating, permanent-magnet)
104:
1PH4 induction motor
107:
1PH7 induction motor
108:
1PH8 induction motor
111:
Induction motor (rotary) for OEMs
200:
1PH8 synchronous motor
206:
1FT6 synchronous motor
207:
1FT7 synchronous motor
222:
Synchronous motor (rotary) for OEMs
236:
1FK6 synchronous motor
237:
1FK7 synchronous motor
444:
Synchronous motor (linear) for OEMs
10000: Motor with DRIVE-CLiQ
10001: Motor with DRIVE-CLiQ 2nd data set
Dependency:
When the motor type is changed, the code number in p0301 may be reset to 0.
If p0300 is changed during quick commissioning (p0010 = 1), then the matching technological application (p0500) is
automatically pre-assigned. This does not occur when commissioning the motor (p0010 = 3). If p0300 = 10000 is
written for a parameter download, p0500 is pre-assigned with DRIVE-CLiQ corresponding to the motor type.
Refer to: p0301
Caution:
If a catalog motor is selected (p0300 >= 100) and an associated motor code number (p0301), then the parame-
ters,that are associated with this list cannot be changed (write protection). The write protection is canceled if the
motor type p0300 is set to a non-Siemens motor that matches p0301 (e.g. p0300 = 2 for p0301 = 2xxxx). Write pro-
tection is automatically canceled when the results of motor data identification are copied to the motor parameters.
r0297
DC link voltage overvoltage threshold / Vdc U_upper_thresh
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
2
Data type:
Unsigned16
Dynamic index:
-
Func. diagram:
8750, 8760,
8850, 8864, 8950, 8964
P-Group:
Converter
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- [V]
- [V]
- [V]
p0300[0...n]
Motor type selection / Mot type sel
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(1, 3)
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
MDS, p0130
Func. diagram:
6310
P-Group:
Motor
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 10001
0
Содержание SINAMICS S110
Страница 1: ...s SINAMICS S110 List Manual 06 2012 SINAMICS ...
Страница 2: ......
Страница 1272: ...List of abbreviations B 1272 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1286: ...Index C 1286 Siemens AG 2012 All Rights Reserved SINAMICS S110 List Manual LH7 06 2012 6SL3097 4AP10 0BP3 ...
Страница 1287: ......