List of parameters
Parameter
1-333
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2188 < p2187
Refer to: p2183, p2187
Refer to: A07926
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2189 > p2190
Refer to: p2184, p2190
Refer to: A07926
Note:
The upper envelope curve is defined by p2185, p2187 and p2189.
Description:
Sets the speed/torque / velocity/force envelope curve for the load monitoring.
Dependency:
The following applies: p2190 < p2189
Refer to: p2184, p2189
Refer to: A07926
Note:
The lower envelope curve is defined by p2186, p2188 and p2190.
Description:
Sets the delay time to evaluate the load monitoring.
p2188[0...n]
Load monitoring torque threshold 2, lower / M_thresh 2 lower
SERVO_S110-CAN
(Ext msg),
SERVO_S110-DP
(Ext msg),
SERVO_S110-PN
(Ext msg)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
8013
P-Group:
Messages
Units group:
7_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Nm]
20000000.00 [Nm]
0.00 [Nm]
p2189[0...n]
Load monitoring torque threshold 3, upper / M_thresh 3 upper
SERVO_S110-CAN
(Ext msg),
SERVO_S110-DP
(Ext msg),
SERVO_S110-PN
(Ext msg)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
8013
P-Group:
Messages
Units group:
7_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Nm]
20000000.00 [Nm]
10000000.00 [Nm]
p2190[0...n]
Load monitoring torque threshold 3, lower / M_thresh 3 lower
SERVO_S110-CAN
(Ext msg),
SERVO_S110-DP
(Ext msg),
SERVO_S110-PN
(Ext msg)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
8013
P-Group:
Messages
Units group:
7_1
Unit selection:
p0505
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Nm]
20000000.00 [Nm]
0.00 [Nm]
p2192[0...n]
Load monitoring delay time / Load monit t_del
SERVO_S110-CAN
(Ext msg),
SERVO_S110-DP
(Ext msg),
SERVO_S110-PN
(Ext msg)
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
8013
P-Group:
Messages
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [s]
65.00 [s]
10.00 [s]