List of parameters
Parameter
1-131
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Value:
0:
No
1:
Yes
Notice:
The inhibit for the reference value calculation is canceled when new motor parameters (e.g. p0305) are entered and
only one drive data set exists (p0180 = 1). This is the case during initial commissioning.
Once the motor and control parameters have been calculated (p0340, p3900), the inhibit for the reference value
calculation is automatically re-activated.
Note:
If value = 0:
The automatic calculation (p0340, p3900) overwrites the reference parameters.
If value = 1:
The automatic calculation (p0340, p3900) does not overwrite the reference parameters.
Description:
This parameter is used to calculate all parameters that depend on the technology of the application (p0500).
All of the parameters are calculated that can also be determined using p0340 = 5.
Value:
0:
No calculation
1:
Complete calculation
Note:
At the end of the calculations, p0578 is automatically set to 0.
Description:
Sets the input terminal for the measuring probe for speed actual value measurement.
Value:
0:
No measuring probe
1:
DI/DO 9 (X132.2)
2:
DI/DO 10 (X132.3)
3:
DI/DO 11 (X132.4)
7:
DI/DO 8 (X132.1)
Dependency:
Refer to: p0728
Refer to: A07498
Note:
The terminal must be set as input (p0728).
If a parameter change is rejected, a check should be performed as to whether the input terminal is already being
used in p0488, p0489, p0493, p0494, p0495, p0680, p2517 or p2518.
DI/DO: Bidirectional Digital Input/Output
Description:
Selects the units for the parameters of the technology controller.
p0578[0...n]
Calculate technology-dependent parameters / Calc tec par
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
C2(5), T
Calculated:
-
Access level:
2
Data type:
Integer16
Dynamic index:
DDS, p0180
Func. diagram:
-
P-Group:
Applications
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p0580
Measuring probe, input terminal / MT input terminal
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Encoder
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 7
0
p0595
Selecting technological units / Select tech units
SERVO_S110-CAN
(Tech_ctrl),
SERVO_S110-DP
(Tech_ctrl),
SERVO_S110-PN
(Tech_ctrl)
Can be changed:
C2(5)
Calculated:
-
Access level:
1
Data type:
Integer16
Dynamic index:
-
Func. diagram:
-
P-Group:
Applications
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
1 32
1