List of parameters
Parameter
1-591
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Note:
Re r9719.0 and r9719.1:
These two bits must be considered together.
- if SOS/SLS (SBH/SG) is de-selected using bit 0, then assignment of bit 1 is irrelevant.
- if SOS/SLS (SBH/SG) is selected using bit 0, then a changeover is made between SOS (SBH) and SLS (SG)
using bit 1.
SLP: Safely-Limited Position / SE: Safe software limit switches
SLS: Safely-Limited Speed / SG: Safely reduced speed
SOS: Safe Operating Stop / SBH: Safe operating stop
SDI: Safe Direction (safe motion direction)
Description:
Control signals for safety-relevant motion monitoring functions integrated in the drive.
Note:
This parameter is only supplied with actual values in the case of Safety Integrated Extended Functions. For Safety
Integrated Basic Functions (SBC, SS1, STO), the value is equal to zero.
Description:
Status signal for safety-relevant motion monitoring functions.
30
SLS (SG) override bit 2
Set
Not set
-
31
SLS (SG) override bit 3
Set
Not set
-
r9720.0...13
CO/BO: SI Motion control signals integrated in the drive / SI Mtn integ STW
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
2840, 2855
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
De-select STO
Yes
No
-
01
De-select SS1
Yes
No
-
02
De-select SS2
Yes
No
-
03
De-select SOS
Yes
No
-
04
De-select SLS
Yes
No
-
07
Acknowledgement
Signal edge active
No
-
09
Select SLS bit 0
Set
Not set
-
10
Select SLS bit 1
Set
Not set
-
12
Deselect SDI positive
Yes
No
2861
13
Deselect SDI negative
Yes
No
2861
r9721.0...15
CO/BO: SI Motion status signals / SI Mtn stat_sig
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dynamic index:
-
Func. diagram:
-
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
SOS or SLS active
Yes
No
-
01
SOS active
Yes
No
-
02
Pulse enable
Deleted
Enabled
-
03
Active SLS stage bit 0
Set
Not set
-
04
Active SLS stage bit 1
Set
Not set
-
05
Velocity below limit value n_x
Yes
No
-
06
Status signals valid
Yes
No
-
07
Safely referenced
Yes
No
-
08
SDI pos active
Yes
No
-
09
SDI neg active
Yes
No
-
12
STOP A or B active
Yes
No
-
13
STOP C active
Yes
No
-
14
STOP D active
Yes
No
-
15
STOP E active
Yes
No
-