List of parameters
Parameter
1-421
© Siemens AG 2012 All Rights Reserved
SINAMICS S110 List Manual (LH7), 06/2012, 6SL3097-4AP10-0BP3
Description:
Sets a fixed value for torque.
Dependency:
Refer to: p2900, p2901
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can, for example, be used to interconnect a supplementary torque.
Description:
Torque constant for the synchronous motor determined by the motor data identification.
This torque constant can be changed after the identification and accepted in p0316 with p1910/p1960 = -3.
Dependency:
Refer to: p0316, r0334, r1937, p1960
Description:
Voltage constant for a synchronous motor determined by the motor data identification.
This voltage constant can be changed after the identification and accepted in p0317 with p1910/p1960 = -3.
Units for rotating synchronous motors: Vrms/(1000 rpm), phase-to-phase
Dependency:
Refer to: r1938, p1960
Description:
Magnetizing current for an induction motor determined by the motor data identification.
This magnetizing current can be changed after the identification and accepted in p0320 with p1910/p1960 = -3.
Dependency:
Refer to: p0320, r0331, p1910, r1948, p1960
p2930[0...n]
CO: Fixed value M [Nm] / Fixed value M [Nm]
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
DDS, p0180
Func. diagram:
1021
P-Group:
Free function blocks
Units group:
7_1
Unit selection:
p0505
Not for motor type:
REL
Scaling:
p2003
Expert list:
1
Min Max
Factory
setting
-100000.00 [Nm]
100000.00 [Nm]
0.00 [Nm]
p3016
MotId torque constant identified / kT ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
28_1
Unit selection:
p0100
Not for motor type:
ASM, REL, FEM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [Nm/A]
100.00 [Nm/A]
0.00 [Nm/A]
p3017
MotId voltage constant identified / kE ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
ASM, REL, FEM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.0 [Vrms]
10000.0 [Vrms]
0.0 [Vrms]
p3020
MotId magnetizing current identified / I_mag ident
SERVO_S110-CAN,
SERVO_S110-DP,
SERVO_S110-PN
Can be changed:
U, T
Calculated:
CALC_MOD_ALL
Access level:
3
Data type:
FloatingPoint32
Dynamic index:
-
Func. diagram:
-
P-Group:
Motor identification
Units group:
-
Unit selection:
-
Not for motor type:
REL, FEM
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 [Arms]
5000.000 [Arms]
0.000 [Arms]